IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

529

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0528 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,011 $3,500 Implemented
OK0528 # 03 Y:1997 03 1997 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $3,099 $4,655 Not Implemented
OK0528 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $962 $114 Implemented
OK0528 # 05 Y:1997 05 1997 USE OPTIMUM THICKNESS INSULATION $747 $166 Implemented
OK0528 # 06 Y:1997 06 1997 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $6,149 $12,500 Not Implemented
OK0528 # 07 Y:1997 07 1997 MOVE PRODUCT USING MECHANICAL MEANS $39,936 $28,000 Not Implemented
KU0456 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,121 $6,407 Implemented
KU0456 # 02 Y:1995 02 1995 INSTALL OCCUPANCY SENSORS $926 $900 Implemented
KU0456 # 03 Y:1995 03 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $292 $408 Implemented
KU0456 # 04 Y:1995 04 1995 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $138 $217 Implemented
KU0456 # 05 Y:1995 05 1995 INCREASE AMOUNT OF CONDENSATE RETURNED $150 $450 Implemented
KU0456 # 06 Y:1995 06 1995 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,740 $3,500 Implemented
KU0451 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,483 $13,216 Implemented
KU0451 # 02 Y:1995 02 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $8,072 $918 Implemented
KU0451 # 03 Y:1995 03 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,560 $300 Implemented
KU0451 # 04 Y:1995 04 1995 METER WASTE WATER $11,589 $5,000 Not Implemented
KU0451 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,568 $3,155 Implemented
KU0451 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,217 $2,780 Implemented
KU0451 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $880 $650 Not Implemented
KU0451 # 08 Y:1995 08 1995 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $491 $90 Not Implemented
KU0451 # 09 Y:1995 09 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $176 $240 Implemented
KU0427 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $160 $107 Implemented
KU0427 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,234 $7,537 Implemented
KU0427 # 01 Y:1994 01 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,297 $0 Implemented
KU0427 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $1,084 $1,980 Not Implemented