IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

202

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0103 # 03 Y:1987 03 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,707 $24,000 Not Implemented
MA0103 # 04 Y:1987 04 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,453 $3,862 Not Implemented
MA0103 # 05 Y:1987 05 1987 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $470 $0 Implemented
MA0103 # 06 Y:1987 06 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $5,019 $15,000 Implemented
MA0103 # 07 Y:1987 07 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,319 $0 Not Implemented
MA0101 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,063 $3,477 Not Implemented
MA0101 # 02 Y:1987 02 1987 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $781 $0 Not Implemented
MA0101 # 03 Y:1987 03 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,436 $1,000 Not Implemented
MA0101 # 04 Y:1987 04 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,559 $5,000 Not Implemented
MA0101 # 05 Y:1987 05 1987 TURN OFF EQUIPMENT WHEN NOT IN USE $1,151 $0 Implemented
MA0101 # 06 Y:1987 06 1987 INSTALL TIMERS AND/OR THERMOSTATS $8,517 $340 Implemented
MA0101 # 07 Y:1987 07 1987 SHUT OFF PILOTS IN STANDBY EQUIPMENT $355 $0 Not Implemented
MA0048 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $592 $180 Implemented
MA0048 # 02 Y:1985 02 1985 INSTALL TURBULATORS $636 $2,200 Implemented
MA0048 # 03 Y:1985 03 1985 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $728 $1,700 Not Implemented
MA0048 # 04 Y:1985 04 1985 RECOVER WASTE HEAT FROM EQUIPMENT $2,960 $2,710 Not Implemented
MA0048 # 05 Y:1985 05 1985 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $4,082 $2,095 Not Implemented
MA0048 # 06 Y:1985 06 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,733 $9,000 Not Implemented
MA0022 # 01 Y:1985 01 1985 HEAT WATER WITH EXHAUST HEAT $2,163 $1,875 Not Implemented
MA0022 # 02 Y:1985 02 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $753 $1,827 Implemented
MA0022 # 03 Y:1985 03 1985 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $160 $154 Implemented
MA0022 # 04 Y:1985 04 1985 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $283 $0 Implemented
MA0022 # 05 Y:1985 05 1985 OPTIMIZE PLANT POWER FACTOR $432 $289 Implemented
MA0022 # 06 Y:1985 06 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,060 $1,190 Not Implemented
MA0003 # 01 Y:1984 01 1984 REPAIR OR REPLACE STEAM TRAPS $14,697 $0 Implemented