Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21,135
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0052 # 02 Y:1986 | 02 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,221 | $2,500 | Implemented |
CO0052 # 03 Y:1986 | 03 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $763 | $1,500 | Implemented |
CO0052 # 04 Y:1986 | 04 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $852 | $300 | Implemented |
CO0052 # 05 Y:1986 | 05 | 1986 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $765 | $400 | Not Implemented |
CO0052 # 06 Y:1986 | 06 | 1986 | IMPROVE LUBRICATION PRACTICES | $3,842 | $0 | Implemented |
CO0052 # 07 Y:1986 | 07 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $111 | $250 | Not Implemented |
CO0052 # 08 Y:1986 | 08 | 1986 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $73 | $30 | Implemented |
CO0052 # 09 Y:1986 | 09 | 1986 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $3,902 | $4,000 | Implemented |
CO0052 # 10 Y:1986 | 10 | 1986 | INSTALL SET-BACK TIMERS | $1,267 | $657 | Implemented |
MA0052 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $187 | $41 | Not Implemented |
MA0052 # 02 Y:1986 | 02 | 1986 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $589 | $900 | Implemented |
MA0052 # 03 Y:1986 | 03 | 1986 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $375 | $0 | Implemented |
MA0052 # 04 Y:1986 | 04 | 1986 | BURN WASTE PAPER FOR HEAT | $31,590 | $40,000 | Not Implemented |
MA0052 # 05 Y:1986 | 05 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $449 | $1,060 | Not Implemented |
MA0052 # 06 Y:1986 | 06 | 1986 | HEAT WATER WITH EXHAUST HEAT | $383 | $1,500 | Implemented |
MA0048 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $592 | $180 | Implemented |
MA0048 # 02 Y:1985 | 02 | 1985 | INSTALL TURBULATORS | $636 | $2,200 | Implemented |
MA0048 # 03 Y:1985 | 03 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $728 | $1,700 | Not Implemented |
MA0048 # 04 Y:1985 | 04 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,960 | $2,710 | Not Implemented |
MA0048 # 05 Y:1985 | 05 | 1985 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,082 | $2,095 | Not Implemented |
MA0048 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,733 | $9,000 | Not Implemented |
MA0044 # 01 Y:1985 | 01 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $760 | $1,390 | Implemented |
MA0044 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,253 | $600 | Implemented |
MA0044 # 03 Y:1985 | 03 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $207 | $200 | Implemented |
MA0044 # 04 Y:1985 | 04 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,311 | $1,470 | Implemented |