Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,785
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0131 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $632 | $2,800 | Not Implemented |
KU0048 # 01 Y:1982 | 01 | 1982 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $29,754 | $15,000 | Implemented |
KU0048 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,256 | $5,941 | Implemented |
KU0048 # 03 Y:1982 | 03 | 1982 | INSULATE BARE EQUIPMENT | $8,484 | $21,600 | Not Implemented |
KU0048 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,580 | $1,400 | Implemented |
KU0048 # 05 Y:1982 | 05 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $13,088 | $13,000 | Implemented |
KU0048 # 06 Y:1982 | 06 | 1982 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,296 | $1,500 | Not Implemented |
OK0043 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58 | $34 | Implemented |
OK0043 # 02 Y:1982 | 02 | 1982 | INSTALL TURBULATORS | $137 | $670 | Not Implemented |
OK0043 # 03 Y:1982 | 03 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $33 | $600 | Implemented |
OK0043 # 04 Y:1982 | 04 | 1982 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,200 | $210 | Implemented |
OK0043 # 05 Y:1982 | 05 | 1982 | HEAT WATER WITH EXHAUST HEAT | $453 | $1,384 | Not Implemented |
UD0034 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,098 | $2,149 | Not Implemented |
UD0034 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $851 | $0 | Implemented |
UD0034 # 03 Y:1982 | 03 | 1982 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $252 | $100 | Not Implemented |
UD0034 # 04 Y:1982 | 04 | 1982 | REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS | $46,072 | $120,000 | Not Implemented |
UD0034 # 05 Y:1982 | 05 | 1982 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $761 | $400 | Not Implemented |
UD0033 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,288 | $386 | Implemented |
UD0033 # 02 Y:1982 | 02 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,030 | $3,140 | Implemented |
UD0033 # 03 Y:1982 | 03 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $84 | $0 | Implemented |
UD0033 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $872 | $250 | Implemented |
TN0117 # 01 Y:1982 | 01 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,898 | $75 | Not Implemented |
TN0117 # 02 Y:1982 | 02 | 1982 | OPTIMIZE PLANT POWER FACTOR | $15,840 | $13,800 | Not Implemented |
TN0117 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,344 | $5,000 | Not Implemented |
TN0117 # 04 Y:1982 | 04 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,835 | $776 | Not Implemented |