Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,647
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0146 # 06 Y:1998 | 06 | 1998 | INSTALL OCCUPANCY SENSORS | $336 | $1,456 | Not Implemented |
SF0146 # 07 Y:1998 | 07 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $862 | $0 | Implemented |
SF0146 # 08 Y:1998 | 08 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $360 | $115 | Implemented |
SF0146 # 09 Y:1998 | 09 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $3,099 | $3,615 | Not Implemented |
SF0143 # 01 Y:1998 | 01 | 1998 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $3,365 | $0 | Implemented |
SF0143 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,986 | $0 | Implemented |
SF0143 # 03 Y:1998 | 03 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $367 | $0 | Implemented |
SF0143 # 04 Y:1998 | 04 | 1998 | USE PHOTOCELL CONTROLS | $6,026 | $2,250 | Implemented |
SF0143 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,067 | $4,684 | Implemented |
SF0143 # 06 Y:1998 | 06 | 1998 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $78,251 | $99,600 | Implemented |
SF0143 # 07 Y:1998 | 07 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,701 | $9,000 | Implemented |
SF0143 # 08 Y:1998 | 08 | 1998 | INSULATE BARE EQUIPMENT | $468 | $1,138 | Implemented |
SF0143 # 09 Y:1998 | 09 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,201 | $34,990 | Not Implemented |
SF0143 # 10 Y:1998 | 10 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $687 | $2,174 | Not Implemented |
SF0134 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,778 | $0 | Implemented |
SF0134 # 02 Y:1998 | 02 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,690 | $1,675 | Not Implemented |
SF0134 # 03 Y:1998 | 03 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $622 | $390 | Implemented |
SF0134 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,279 | $2,814 | Implemented |
SF0134 # 05 Y:1998 | 05 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,457 | $30,000 | Implemented |
SF0134 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,458 | $71,304 | Implemented |
SF0134 # 07 Y:1998 | 07 | 1998 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $3,216 | $8,500 | Implemented |
SF0134 # 08 Y:1998 | 08 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,339 | $250 | Implemented |
SF0134 # 09 Y:1998 | 09 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,634 | $250 | Not Implemented |
SF0134 # 10 Y:1998 | 10 | 1998 | METER WASTE WATER | $5,934 | $4,500 | Not Implemented |
SF0134 # 11 Y:1998 | 11 | 1998 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $17,498 | $1,140 | Implemented |