Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
245
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0778 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,155 | $9,815 | Not Implemented |
GT0778 # 06 Y:2004 | 06 | 2004 | CONTROL PRESSURE ON STEAMER OPERATIONS | $5,788 | $13,000 | Not Implemented |
GT0778 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $719 | $600 | Not Implemented |
GT0778 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $927 | $600 | Implemented |
GT0778 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,134 | $100 | Not Implemented |
GT0778 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,032 | $3,228 | Implemented |
GT0778 # 01 Y:2004 | 01 | 2004 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $6,613 | $33,628 | Not Implemented |
GT0736 # 07 Y:2002 | 07 | 2002 | COVER OPEN TANKS | $3,121 | $6,000 | Not Implemented |
GT0736 # 10 Y:2002 | 10 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,745 | $31,000 | Not Implemented |
GT0736 # 09 Y:2002 | 09 | 2002 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $8,580 | $0 | Implemented |
GT0736 # 08 Y:2002 | 08 | 2002 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $44,595 | $27,000 | Not Implemented |
GT0736 # 06 Y:2002 | 06 | 2002 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $8,300 | $0 | Implemented |
GT0736 # 05 Y:2002 | 05 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,344 | $0 | Not Implemented |
GT0736 # 04 Y:2002 | 04 | 2002 | BURN A LESS EXPENSIVE GRADE OF FUEL | $38,000 | $38,000 | Not Implemented |
GT0736 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $33,702 | $5,000 | Implemented |
GT0736 # 02 Y:2002 | 02 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $384 | $500 | Implemented |
GT0736 # 01 Y:2002 | 01 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,485 | $0 | Not Implemented |
GT0720 # 09 Y:2001 | 09 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $93,750 | $1,700 | Not Implemented |
GT0720 # 08 Y:2001 | 08 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,740 | $0 | Not Implemented |
GT0720 # 01 Y:2001 | 01 | 2001 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $337 | $1,000 | Implemented |
GT0720 # 02 Y:2001 | 02 | 2001 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,475 | $600 | Implemented |
GT0720 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $467 | $943 | Not Implemented |
GT0720 # 06 Y:2001 | 06 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $658 | $982 | Not Implemented |
GT0720 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,472 | $6,151 | Implemented |
GT0720 # 07 Y:2001 | 07 | 2001 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,320 | $50 | Implemented |