IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,939

matching recommendations
Reset
SIC 201 Meat Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0308 # 01 Y:2005 01 2005 REPAIR AND ELIMINATE STEAM LEAKS $1,671 $0 Implemented
SF0308 # 02 Y:2005 02 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $521 $0 Not Implemented
SF0308 # 03 Y:2005 03 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,198 $430 Not Implemented
SF0308 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,813 $1,512 Implemented
SF0308 # 05 Y:2005 05 2005 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $325 $415 Not Implemented
SF0308 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,381 $9,206 Implemented
SF0308 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $455 $1,925 Implemented
UM0283 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,568 $6,878 Implemented
UM0283 # 02 Y:2005 02 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,056 $2,500 Implemented
UM0283 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,024 $300 Implemented
UM0283 # 04 Y:2005 04 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $873 $3,000 Not Implemented
UM0283 # 05 Y:2005 05 2005 AIR CONDITION ONLY SPACE NECESSARY $793 $2,117 Not Implemented
MS0274 # 01 Y:2005 01 2005 HEAT WATER WITH EXHAUST HEAT $35,536 $19,550 Not Implemented
MS0274 # 02 Y:2005 02 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $8,485 $5,832 Not Implemented
MS0274 # 03 Y:2005 03 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,356 $15,064 Not Implemented
MS0274 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,508 $2,000 Not Implemented
MS0274 # 05 Y:2005 05 2005 REPAIR AND ELIMINATE STEAM LEAKS $5,356 $94 Not Implemented
MS0274 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,129 $7,926 Not Implemented
MS0274 # 07 Y:2005 07 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,110 $2,387 Not Implemented
MS0274 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,342 $7,035 Not Implemented
MS0274 # 09 Y:2005 09 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,636 $5,788 Not Implemented
MS0274 # 10 Y:2005 10 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,135 $0 Not Implemented
MS0274 # 11 Y:2005 11 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $672 $223 Not Implemented
MS0274 # 12 Y:2005 12 2005 AIR CONDITION ONLY SPACE NECESSARY $425 $120 Not Implemented
SF0301 # 01 Y:2005 01 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,466 $0 Not Implemented