IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

781

matching recommendations
Reset
SIC 2011 Meat Packing Plants
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0262 # 10 Y:2004 10 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $603 $90 Not Implemented
BD0262 # 11 Y:2004 11 2004 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $32,008 $100 Not Implemented
BD0262 # 12 Y:2004 12 2004 INSTALL AUTOMATIC PACKING EQUIPMENT $436,800 $99,000 Not Implemented
BD0262 # 13 Y:2004 13 2004 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $13,000 $300 Implemented
BD0262 # 14 Y:2004 14 2004 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $11,289 $5,500 Implemented
BD0262 # 15 Y:2004 15 2004 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $1,724 $250 Not Implemented
BD0262 # 16 Y:2004 16 2004 PAY BILLS ON TIME TO AVOID LATE FEES $2,231 $0 Not Implemented
BD0262 # 17 Y:2004 17 2004 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $560 $500 Not Implemented
OK0687 # 01 Y:2004 01 2004 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $7,853 $8,000 Not Implemented
OK0687 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,548 $825 Not Implemented
OK0687 # 03 Y:2004 03 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,490 $5,298 Not Implemented
OK0687 # 04 Y:2004 04 2004 INSTALL OCCUPANCY SENSORS $1,980 $269 Not Implemented
OK0687 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,199 $287 Not Implemented
OK0687 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,275 $8,882 Not Implemented
UF0340 # 01 Y:2004 01 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $122,549 $170,000 Not Implemented
UF0340 # 02 Y:2004 02 2004 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $617,545 $2,420,000 Not Implemented
UF0340 # 03 Y:2004 03 2004 REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE $29,744 $98,000 Not Implemented
UF0340 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $38,590 $48,289 Implemented
UF0340 # 05 Y:2004 05 2004 OPTIMIZE PLANT POWER FACTOR $10,480 $40,000 Implemented
UF0340 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,682 $400 Implemented
UF0340 # 07 Y:2004 07 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,109 $37,572 Not Implemented
UF0340 # 08 Y:2004 08 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,678 $7,900 Implemented
IC0072 # 01 Y:2004 01 2004 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $30,046 $118,316 n/a
IC0072 # 02 Y:2004 02 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,893 $6,541 n/a
IC0072 # 03 Y:2004 03 2004 INSTALL TIMERS AND/OR THERMOSTATS $1,003 $398 n/a