Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

774

matching recommendations
Reset
SIC 2011 Meat Packing Plants
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0251 # 06 Y:2000 06 2000 INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE $44,000 $3,034 Implemented
UF0251 # 07 Y:2000 07 2000 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $940 $0 Not Implemented
UF0251 # 08 Y:2000 08 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $378 $0 Implemented
UF0251 # 09 Y:2000 09 2000 $418 $280 Implemented
UF0251 # 10 Y:2000 10 2000 $104,000 $110,000 Not Implemented
NC0172 # 01 Y:1999 01 1999 $125,000 $52,000 Not Implemented
NC0172 # 02 Y:1999 02 1999 OPERATE BOILERS ON HIGH FIRE SETTING $4,485 $0 Not Implemented
NC0172 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $636 $476 Not Implemented
NC0172 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,986 $40 Not Implemented
NC0172 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $71,741 $40,000 Not Implemented
NC0172 # 06 Y:1999 06 1999 AVOID REWINDING MOTORS MORE THAN TWICE $10,026 $25,900 Not Implemented
NC0172 # 07 Y:1999 07 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $188 $300 Not Implemented
NC0172 # 08 Y:1999 08 1999 MINIMIZE WATER USAGE $2,627 $2,500 Not Implemented
NC0172 # 09 Y:1999 09 1999 MINIMIZE WATER USAGE $1,235 $1,200 Not Implemented
DS0101 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,339 $10,895 Not Implemented
DS0101 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,905 $1,750 Not Implemented
DS0101 # 03 Y:1998 03 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,424 $820 Not Implemented
DS0101 # 04 Y:1998 04 1998 MINIMIZE WATER USAGE $2,739 $0 Not Implemented
DS0101 # 05 Y:1998 05 1998 MINIMIZE WATER USAGE $5,125 $-6,000 Not Implemented
DS0101 # 06 Y:1998 06 1998 USE MECHANICAL STRIPPING METHODS $675 $2,295 Not Implemented
ME0230 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,882 $10,074 Not Implemented
ME0230 # 02 Y:1997 02 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,038 $0 Not Implemented
ME0230 # 03 Y:1997 03 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,022 $0 Not Implemented
ME0230 # 04 Y:1997 04 1997 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $973 $400 Not Implemented
ME0230 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $636 $916 Not Implemented