Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20
matching recommendationsSIC | 2013 | Sausages And Other Prepared Meats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0506 # 06 Y:2006 | 06 | 2006 | $2,300 | $0 | Implemented | |
OR0506 # 05 Y:2006 | 05 | 2006 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,200 | $3,600 | Implemented |
OR0506 # 04 Y:2006 | 04 | 2006 | $11,400 | $2,700 | Implemented | |
OR0506 # 03 Y:2006 | 03 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,000 | $0 | Implemented |
OR0506 # 02 Y:2006 | 02 | 2006 | $9,000 | $2,100 | Implemented | |
OR0506 # 01 Y:2006 | 01 | 2006 | $360,000 | $2,100 | Implemented | |
IA0396 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,228 | $600 | Implemented |
IA0396 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $302 | $3,899 | Implemented |
IA0396 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,836 | $4,661 | Implemented |
IA0396 # 05 Y:2006 | 05 | 2006 | DISCONNECT BALLASTS | $810 | $83 | Implemented |
IA0396 # 07 Y:2006 | 07 | 2006 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $6,338 | $500 | Implemented |
IA0396 # 08 Y:2006 | 08 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,234 | $1,702 | Implemented |
LE0238 # 05 Y:2006 | 05 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,103 | $2,500 | Implemented |
LE0238 # 11 Y:2006 | 11 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,065 | $90 | Implemented |
LE0238 # 07 Y:2006 | 07 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,609 | $45,000 | Implemented |
LE0238 # 06 Y:2006 | 06 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,870 | $3,000 | Implemented |
LE0238 # 03 Y:2006 | 03 | 2006 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $335,810 | $500 | Implemented |
IA0380 # 01 Y:2006 | 01 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $336 | $25 | Implemented |
IA0380 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $262 | $879 | Implemented |
IA0380 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $685 | $215 | Implemented |