IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

64

matching recommendations
Reset
SIC 2015 Poultry Slaughtering And Processing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0799 # 08 Y:2020 08 2020 USE SYNTHETIC LUBRICANT $480 $36 Implemented
AM0799 # 05 Y:2020 05 2020 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,334 $13 Not Implemented
AM0799 # 07 Y:2020 07 2020 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $700 $70 Not Implemented
AM0799 # 04 Y:2020 04 2020 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $8,900 $1,750 Implemented
AM0799 # 06 Y:2020 06 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,080 $5,060 Implemented
AM0799 # 03 Y:2020 03 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,112 $1,500 Implemented
AM0799 # 02 Y:2020 02 2020 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $12,800 $15,000 Implemented
AM0799 # 01 Y:2020 01 2020 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $726,150 $100 Implemented
AM0747 # 02 Y:2018 02 2018 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $56,800 $121,500 Implemented
AM0747 # 03 Y:2018 03 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,900 $44,160 Implemented
AM0747 # 05 Y:2018 05 2018 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,680 $30 Not Implemented
AM0747 # 04 Y:2018 04 2018 OPTIMIZE PLANT POWER FACTOR $12,800 $39,100 Implemented
AM0747 # 01 Y:2018 01 2018 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $170,240 $376,350 Not Implemented
AM0745 # 06 Y:2018 06 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,060 $500 Not Implemented
AM0745 # 07 Y:2018 07 2018 USE SYNTHETIC LUBRICANT $4,580 $0 Not Implemented
AM0745 # 09 Y:2018 09 2018 USE PHOTOCELL CONTROLS $2,000 $1,740 Not Implemented
AM0745 # 08 Y:2018 08 2018 PAY UTILITY BILLS ON TIME $2,870 $0 Not Implemented
AM0745 # 01 Y:2018 01 2018 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $45,900 $0 Not Implemented
AM0745 # 02 Y:2018 02 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,800 $44,650 Not Implemented
AM0745 # 03 Y:2018 03 2018 OPTIMIZE PLANT POWER FACTOR $19,915 $40,190 Not Implemented
AM0745 # 04 Y:2018 04 2018 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,600 $2,320 Not Implemented
AM0745 # 05 Y:2018 05 2018 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,730 $20 Not Implemented
OK0914 # 01 Y:2015 01 2015 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,502 $11,500 Not Implemented
OK0914 # 02 Y:2015 02 2015 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,411 $32,000 Not Implemented
OK0914 # 03 Y:2015 03 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $4,010 $2,099 Not Implemented