Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

718

matching recommendations
Reset
SIC 2015 Poultry Slaughtering And Processing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0215 # 07 Y:1987 07 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,230 $5,203 Implemented
KU0215 # 08 Y:1987 08 1987 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $6,109 $1,000 Not Implemented
GT0299 # 01 Y:1986 01 1986 INSULATE BARE EQUIPMENT $818 $2,688 Implemented
GT0299 # 02 Y:1986 02 1986 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,563 $0 Implemented
GT0299 # 03 Y:1986 03 1986 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $20,878 $34,000 Implemented
GT0299 # 04 Y:1986 04 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $574 $983 Not Implemented
GT0299 # 05 Y:1986 05 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,032 $4,245 Implemented
GT0299 # 06 Y:1986 06 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $488 $219 Not Implemented
GT0299 # 07 Y:1986 07 1986 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $9,163 $3,000 Implemented
CO0066 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,554 $250 Implemented
CO0066 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $6,698 $6,000 Not Implemented
CO0066 # 03 Y:1986 03 1986 INSTALL TURBULATORS $1,622 $600 Implemented
CO0066 # 04 Y:1986 04 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $17,849 $4,900 Not Implemented
CO0066 # 05 Y:1986 05 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,444 $2,300 Not Implemented
CO0066 # 06 Y:1986 06 1986 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $2,182 $1,825 Not Implemented
CO0066 # 07 Y:1986 07 1986 INSTALL / REPAIR INSULATION ON STEAM LINES $2,052 $1,570 Not Implemented
CO0066 # 08 Y:1986 08 1986 REPAIR OR REPLACE STEAM TRAPS $125 $200 Implemented
CO0066 # 09 Y:1986 09 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,151 $1,148 Not Implemented
CO0066 # 10 Y:1986 10 1986 HEAT WATER WITH EXHAUST HEAT $1,716 $8,000 Not Implemented
GT0279 # 01 Y:1986 01 1986 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $9,580 $17,200 Implemented
GT0279 # 02 Y:1986 02 1986 RECOVER WASTE HEAT FROM EQUIPMENT $43,200 $41,600 Implemented
GT0279 # 03 Y:1986 03 1986 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $2,480 $500 Implemented
GT0279 # 04 Y:1986 04 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,140 $500 Implemented
GT0279 # 05 Y:1986 05 1986 INSTALL / REPAIR INSULATION ON STEAM LINES $1,090 $1,120 Implemented
GT0279 # 06 Y:1986 06 1986 COVER OPEN TANKS $1,560 $3,000 Implemented