Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

210

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0211 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $308 $978 Implemented
OR0211 # 06 Y:1994 06 1994 OPTIMIZE PLANT POWER FACTOR $2,527 $2,400 Implemented
OR0211 # 07 Y:1994 07 1994 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $14,967 $12,300 Implemented
OR0211 # 08 Y:1994 08 1994 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $196 $900 Implemented
OR0211 # 09 Y:1994 09 1994 REDUCE FLUID FLOW RATES $6,185 $7,611 Implemented
OR0211 # 10 Y:1994 10 1994 RECOVER AND REUSE COOLING WATER $1,787 $2,824 Not Implemented
OR0188 # 01 Y:1993 01 1993 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,784 $15,000 Implemented
OR0188 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,389 $1,320 Implemented
OR0188 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $1,031 $750 Not Implemented
OR0188 # 04 Y:1993 04 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $17 $84 Implemented
OR0165 # 01 Y:1992 01 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $4,045 $500 Implemented
OR0165 # 02 Y:1992 02 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,788 $0 Implemented
OR0165 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,356 $0 Not Implemented
OR0165 # 04 Y:1992 04 1992 OPTIMIZE PLANT POWER FACTOR $1,074 $2,250 Implemented
OR0165 # 05 Y:1992 05 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $830 $0 Implemented
OR0165 # 06 Y:1992 06 1992 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $320 $824 Implemented
OR0156 # 01 Y:1992 01 1992 CHECK FOR ACCURACY OF UTILITY / POWER METERS $23,479 $0 Not Implemented
OR0156 # 02 Y:1992 02 1992 USE MINIMUM STEAM OPERATING PRESSURE $473 $0 Implemented
OR0156 # 03 Y:1992 03 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,966 $1,000 Implemented
OR0156 # 04 Y:1992 04 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $200 $0 Implemented
OR0156 # 05 Y:1992 05 1992 INSTALL SET-BACK TIMERS $387 $360 Not Implemented
OR0156 # 06 Y:1992 06 1992 RECOVER AND REUSE COOLING WATER $3,527 $5,105 Implemented
OR0156 # 07 Y:1992 07 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $102 $164 Implemented
OR0122 # 01 Y:1991 01 1991 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,529 $0 Implemented
OR0122 # 02 Y:1991 02 1991 OPTIMIZE PLANT POWER FACTOR $1,640 $1,700 Implemented