Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

103

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0562 # 01 Y:2016 01 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33,778 $52,400 Implemented
IA0562 # 02 Y:2016 02 2016 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $11,222 $7,477 Implemented
IA0562 # 03 Y:2016 03 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,873 $750 Implemented
IA0562 # 04 Y:2016 04 2016 DIRECT WARMEST AIR TO COMBUSTION INTAKE $4,205 $2,457 Implemented
IA0562 # 06 Y:2016 06 2016 INSTALL / REPAIR INSULATION ON STEAM LINES $1,171 $2,324 Not Implemented
IA0562 # 07 Y:2016 07 2016 INSTALL OCCUPANCY SENSORS $721 $1,740 Implemented
IA0562 # 05 Y:2016 05 2016 DISCONNECT BALLASTS $2,687 $980 Not Implemented
IA0459 # 03 Y:2010 03 2010 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $21,406 $10,000 Not Implemented
IA0459 # 07 Y:2010 07 2010 REPAIR AND ELIMINATE STEAM LEAKS $700 $1,000 Implemented
IA0459 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,460 $3,923 Implemented
IA0459 # 09 Y:2010 09 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,256 $500 Implemented
IA0459 # 06 Y:2010 06 2010 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $2,057 $1,500 Not Implemented
IA0459 # 10 Y:2010 10 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,434 $450 Not Implemented
IA0459 # 08 Y:2010 08 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,899 $329 Implemented
IA0459 # 04 Y:2010 04 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $23,761 $1,000 Implemented
IA0459 # 05 Y:2010 05 2010 DIRECT WARMEST AIR TO COMBUSTION INTAKE $7,611 $1,500 Not Implemented
IA0459 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $1,643 $1,978 Not Implemented
IA0325 # 06 Y:2003 06 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $508 $25 Implemented
IA0325 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,473 $11,035 Implemented
IA0325 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $957 $245 Implemented
IA0325 # 01 Y:2003 01 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $18,064 $1,000 Implemented
IA0325 # 08 Y:2003 08 2003 INSTALL OCCUPANCY SENSORS $53 $133 Not Implemented
IA0325 # 09 Y:2003 09 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $643 $433 Not Implemented
IA0325 # 04 Y:2003 04 2003 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $7,965 $4,000 Not Implemented
IA0325 # 02 Y:2003 02 2003 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,881 $2,200 Not Implemented