Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0023 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,785 | $23,530 | Not Implemented |
TT0023 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,401 | $13,400 | Not Implemented |
TT0023 # 10 Y:2008 | 10 | 2008 | OPTIMIZE PLANT POWER FACTOR | $15,500 | $32,800 | Not Implemented |
TT0023 # 09 Y:2008 | 09 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $1,750 | $1,600 | Implemented |
TT0023 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,275 | $4,900 | Implemented |
TT0023 # 07 Y:2008 | 07 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,600 | $8,310 | Implemented |
TT0023 # 06 Y:2008 | 06 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $37,200 | $1,000 | Implemented |
TT0023 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $55,100 | $20,000 | Implemented |
TT0023 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,685 | $7,344 | Not Implemented |
TT0023 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,700 | $11,100 | Not Implemented |
UF0414 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $255 | $39 | Implemented |
UF0414 # 04 Y:2008 | 04 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,808 | $15,562 | Implemented |
UF0414 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $44,500 | $13,000 | Implemented |
UF0414 # 02 Y:2008 | 02 | 2008 | REDUCE DELIVERY SCHEDULES | $89,700 | $6,652 | Not Implemented |
UF0414 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,527 | $7,379 | Implemented |
UF0414 # 06 Y:2008 | 06 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,447 | $371 | Implemented |
UF0414 # 07 Y:2008 | 07 | 2008 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $13,994 | $10,000 | Not Implemented |
UF0414 # 08 Y:2008 | 08 | 2008 | BURN A LESS EXPENSIVE GRADE OF FUEL | $217,282 | $100,000 | Not Implemented |
UF0412 # 08 Y:2008 | 08 | 2008 | INSTALL SET-BACK TIMERS | $15,103 | $4,916 | Implemented |
UF0412 # 09 Y:2008 | 09 | 2008 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $1,822 | $10,480 | Implemented |
UF0412 # 06 Y:2008 | 06 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $2,521 | $0 | Implemented |
UF0412 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $17,781 | $615 | Implemented |
UF0412 # 04 Y:2008 | 04 | 2008 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,855 | $795 | Not Implemented |
UF0412 # 03 Y:2008 | 03 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $12,505 | $731 | Implemented |
UF0412 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,683 | $42,414 | Implemented |