Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
212
matching recommendationsSIC | 2022 | Cheese, Natural And Processed |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0434 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $7,897 | $1,387 | Implemented |
SD0434 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $799 | $100 | Implemented |
IA0451 # 01 Y:2010 | 01 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,327 | $1,729 | Implemented |
IA0451 # 02 Y:2010 | 02 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,102 | $1,000 | Implemented |
IA0451 # 03 Y:2010 | 03 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,659 | $140 | Implemented |
IA0451 # 04 Y:2010 | 04 | 2010 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $3,433 | $500 | Implemented |
IA0451 # 05 Y:2010 | 05 | 2010 | REDUCE VENTILATION AIR | $1,483 | $2,000 | Implemented |
UW0035 # 05 Y:2010 | 05 | 2010 | INSULATE BARE EQUIPMENT | $3,700 | $2,000 | Implemented |
UW0035 # 03 Y:2010 | 03 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,058 | $1 | Implemented |
UW0035 # 02 Y:2010 | 02 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $28,000 | $77,000 | Implemented |
AM0560 # 03 Y:2009 | 03 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,130 | $70,250 | Implemented |
AM0560 # 02 Y:2009 | 02 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,860 | $25,000 | Implemented |
AM0560 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,120 | $2,500 | Implemented |
AM0560 # 05 Y:2009 | 05 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $16,000 | $1,900 | Implemented |
AM0560 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $10,970 | $2,190 | Implemented |
AM0560 # 07 Y:2009 | 07 | 2009 | USE SYNTHETIC LUBRICANT | $2,715 | $0 | Implemented |
AM0560 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,495 | $670 | Implemented |
AM0560 # 09 Y:2009 | 09 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $620 | $0 | Implemented |
IA0398 # 09 Y:2006 | 09 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $255 | $340 | Implemented |
IA0398 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,700 | $39 | Implemented |
IA0398 # 04 Y:2006 | 04 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,710 | $1,000 | Implemented |
IA0398 # 11 Y:2006 | 11 | 2006 | INSULATE BARE EQUIPMENT | $742 | $580 | Implemented |
IA0398 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $9,808 | $6,000 | Implemented |
IA0398 # 07 Y:2006 | 07 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $7,646 | $1,000 | Implemented |
IA0398 # 08 Y:2006 | 08 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $861 | $555 | Implemented |