Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 2022 | Cheese, Natural And Processed |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0119 # 01 Y:1998 | 01 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,323 | $0 | Not Implemented |
DS0119 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $985 | $1,000 | Implemented |
DS0119 # 03 Y:1998 | 03 | 1998 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $6,912 | $2,400 | Implemented |
DS0119 # 04 Y:1998 | 04 | 1998 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $14,505 | $15,260 | Not Implemented |
DS0119 # 05 Y:1998 | 05 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $910 | $200 | Implemented |
DS0119 # 06 Y:1998 | 06 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $20,000 | $1,000 | Not Implemented |
SF0143 # 10 Y:1998 | 10 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $687 | $2,174 | Not Implemented |
SF0143 # 09 Y:1998 | 09 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,201 | $34,990 | Not Implemented |
SF0143 # 08 Y:1998 | 08 | 1998 | INSULATE BARE EQUIPMENT | $468 | $1,138 | Implemented |
SF0143 # 07 Y:1998 | 07 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,701 | $9,000 | Implemented |
SF0143 # 06 Y:1998 | 06 | 1998 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $78,251 | $99,600 | Implemented |
SF0143 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,067 | $4,684 | Implemented |
SF0143 # 04 Y:1998 | 04 | 1998 | USE PHOTOCELL CONTROLS | $6,026 | $2,250 | Implemented |
SF0143 # 03 Y:1998 | 03 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $367 | $0 | Implemented |
SF0143 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,986 | $0 | Implemented |
SF0143 # 01 Y:1998 | 01 | 1998 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $3,365 | $0 | Implemented |
DS0109 # 07 Y:1998 | 07 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $400,359 | $200,000 | Implemented |
DS0109 # 06 Y:1998 | 06 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,325 | $50 | Not Implemented |
DS0109 # 05 Y:1998 | 05 | 1998 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $4,740 | $1,500 | Implemented |
DS0109 # 04 Y:1998 | 04 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $250 | $250 | Implemented |
DS0109 # 03 Y:1998 | 03 | 1998 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $10,041 | $13,000 | Implemented |
DS0109 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,907 | $1,500 | Implemented |
DS0109 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,776 | $13,369 | Not Implemented |