Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 1998 |
Principal Product | Cheese |
NAICS | n/a |
SIC | 2022 - Cheese, Natural And Processed |
Sales | $10,000,000-$50,000,000 |
# of Employees | 162 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 60,000,000 Pounds |
Production Hrs. Annual | 7,896 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $752,487 | 16,400,059 | kWh | $0.05 |
Electricity Demand | $317,718 | 28,922 | kW-months/year | $10.99 |
Natural Gas | $598,016 | 163,973 | MMBtu | $3.65 |
TOTAL ENERGY COSTS | $1,953,733 | |||
RECOMMENDED SAVINGS* | $117,119 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $102,231 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1231 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS |
Savings: $3,365 Cost: - |
- | - | - | - | - | - | $3,365 | 1,142 |
- - kWh |
- - kW-months/year |
- - $ |
$3,365 1,142 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,986 Cost: - |
$2,346 | 51,290 | $640 | 58 | - | - | - | - |
$2,346 51,290 kWh |
$640 58 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $367 Cost: - |
- | - | - | - | $367 | - | - | - |
- - kWh |
- - kW-months/year |
$367 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $6,026 Cost: $2,250 |
$4,744 | 103,458 | $1,282 | 117 | - | - | - | - |
$4,744 103,458 kWh |
$1,282 117 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,067 Cost: $4,684 |
$3,712 | 80,305 | $1,355 | 124 | - | - | - | - |
$3,712 80,305 kWh |
$1,355 124 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $78,251 Cost: $99,600 |
$101,367 | 2,208,968 | $36,877 | 3,357 | - | - | $(-59,993) | (-16,450) |
$101,367 2,208,968 kWh |
$36,877 3,357 kW-months/year |
- - $ |
$(-59,993) (-16,450) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $5,701 Cost: $9,000 |
$4,569 | 99,648 | $1,132 | 103 | - | - | - | - |
$4,569 99,648 kWh |
$1,132 103 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $468 Cost: $1,138 |
- | - | - | - | - | - | $468 | 128 |
- - kWh |
- - kW-months/year |
- - $ |
$468 128 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,201 Cost: $34,990 |
$10,279 | 223,916 | $3,922 | 357 | - | - | - | - |
$10,279 223,916 kWh |
$3,922 357 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $687 Cost: $2,174 |
$815 | 17,878 | $148 | 14 | - | - | $(-276) | (-76) |
$815 17,878 kWh |
$148 14 kW-months/year |
- - $ |
$(-276) (-76) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $117,119 Cost: $153,836 |
$127,832 | 2,785,463 | $45,356 | 4,130 | $367 | - | $(-56,436) | (-15,256) | $127,832 2,785,463 kWh |
$45,356 4,130 kW-months/year |
$367 - $ |
$(-56,436) (-15,256) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $102,231 Cost: $116,672 |
$116,738 | 2,543,669 | $41,286 | 3,759 | $367 | - | $(-56,160) | (-15,180) | $116,738 2,543,669 kWh |
$41,286 3,759 kW-months/year |
$367 - $ |
$(-56,160) (-15,180) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |