Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
278
matching recommendationsSIC | 2023 | Dry, Condensed, Evaporated Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0112 # 07 Y:2013 | 07 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,737 | $0 | Not Implemented |
MZ0112 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,024 | $1,150 | Not Implemented |
MZ0112 # 05 Y:2013 | 05 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $48,000 | $2,270 | Implemented |
MZ0112 # 03 Y:2013 | 03 | 2013 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $4,329 | $0 | Not Implemented |
MZ0112 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $6,417 | $3,000 | Implemented |
MZ0112 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,576 | $14,260 | Implemented |
IA0459 # 08 Y:2010 | 08 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,899 | $329 | Implemented |
IA0459 # 07 Y:2010 | 07 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $700 | $1,000 | Implemented |
IA0459 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,460 | $3,923 | Implemented |
IA0459 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $1,643 | $1,978 | Not Implemented |
IA0459 # 03 Y:2010 | 03 | 2010 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $21,406 | $10,000 | Not Implemented |
IA0459 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,256 | $500 | Implemented |
IA0459 # 10 Y:2010 | 10 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,434 | $450 | Not Implemented |
IA0459 # 06 Y:2010 | 06 | 2010 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,057 | $1,500 | Not Implemented |
IA0459 # 05 Y:2010 | 05 | 2010 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $7,611 | $1,500 | Not Implemented |
IA0459 # 04 Y:2010 | 04 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $23,761 | $1,000 | Implemented |
TT0023 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $55,100 | $20,000 | Implemented |
TT0023 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,275 | $4,900 | Implemented |
TT0023 # 09 Y:2008 | 09 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $1,750 | $1,600 | Implemented |
TT0023 # 10 Y:2008 | 10 | 2008 | OPTIMIZE PLANT POWER FACTOR | $15,500 | $32,800 | Not Implemented |
TT0023 # 07 Y:2008 | 07 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,600 | $8,310 | Implemented |
TT0023 # 06 Y:2008 | 06 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $37,200 | $1,000 | Implemented |
TT0023 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,685 | $7,344 | Not Implemented |
TT0023 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,401 | $13,400 | Not Implemented |
TT0023 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,785 | $23,530 | Not Implemented |