Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
963
matching recommendationsSIC | 2026 | Fluid Milk |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0309 # 06 Y:2010 | 06 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,925 | $0 | Implemented |
LE0309 # 01 Y:2010 | 01 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $189,768 | $90,000 | Not Implemented |
LE0309 # 02 Y:2010 | 02 | 2010 | INSULATE BARE EQUIPMENT | $23,403 | $5,772 | Implemented |
LE0309 # 03 Y:2010 | 03 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $21,770 | $250 | Implemented |
LE0309 # 05 Y:2010 | 05 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,117 | $30,000 | Not Implemented |
LE0309 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,657 | $1,000 | Implemented |
LE0309 # 04 Y:2010 | 04 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,145 | $20,000 | Not Implemented |
LE0309 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,018 | $2,431 | Implemented |
LE0309 # 08 Y:2010 | 08 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,494 | $40 | Implemented |
UF0412 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,683 | $42,414 | Implemented |
UF0412 # 10 Y:2008 | 10 | 2008 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $95,676 | $20,000 | Not Implemented |
UF0412 # 01 Y:2008 | 01 | 2008 | INSTALL OCCUPANCY SENSORS | $207 | $79 | Not Implemented |
UF0412 # 09 Y:2008 | 09 | 2008 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $1,822 | $10,480 | Implemented |
UF0412 # 04 Y:2008 | 04 | 2008 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,855 | $795 | Not Implemented |
UF0412 # 07 Y:2008 | 07 | 2008 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,081 | $534 | Not Implemented |
UF0412 # 11 Y:2008 | 11 | 2008 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,359 | $4,246 | Implemented |
UF0412 # 06 Y:2008 | 06 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $2,521 | $0 | Implemented |
UF0412 # 03 Y:2008 | 03 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $12,505 | $731 | Implemented |
UF0412 # 08 Y:2008 | 08 | 2008 | INSTALL SET-BACK TIMERS | $15,103 | $4,916 | Implemented |
UF0412 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $17,781 | $615 | Implemented |
OR0518 # 03 Y:2007 | 03 | 2007 | INSULATE BARE EQUIPMENT | $840 | $4,100 | Not Implemented |
OR0518 # 02 Y:2007 | 02 | 2007 | INSTALL OCCUPANCY SENSORS | $1,020 | $2,050 | Implemented |
OR0518 # 01 Y:2007 | 01 | 2007 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $51,600 | $120,000 | Not Implemented |
UF0398 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $806 | $118 | Not Implemented |
UF0398 # 05 Y:2007 | 05 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $4,676 | $218 | Not Implemented |