Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
64
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0199 # 01 Y:2004 | 01 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $33,535 | $960 | Implemented |
LL0199 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $25,020 | $2,910 | Implemented |
LL0199 # 03 Y:2004 | 03 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $13,735 | $304 | Implemented |
LL0199 # 04 Y:2004 | 04 | 2004 | OPTIMIZE PLANT POWER FACTOR | $4,382 | $24,514 | Not Implemented |
LL0199 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,985 | $720 | Implemented |
LL0199 # 07 Y:2004 | 07 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $544 | $585 | Implemented |
LL0199 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $292 | $120 | Implemented |
LL0199 # 09 Y:2004 | 09 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $41,244 | $0 | Implemented |
LL0199 # 10 Y:2004 | 10 | 2004 | $4,740 | $5,697 | Implemented | |
LL0139 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $457 | $754 | Not Implemented |
LL0139 # 07 Y:2002 | 07 | 2002 | PAY UTILITY BILLS ON TIME | $945 | $0 | Implemented |
LL0139 # 06 Y:2002 | 06 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,786 | $0 | Implemented |
LL0139 # 05 Y:2002 | 05 | 2002 | INSULATE BARE EQUIPMENT | $225 | $378 | Not Implemented |
LL0139 # 03 Y:2002 | 03 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,243 | $4,465 | Not Implemented |
LL0139 # 02 Y:2002 | 02 | 2002 | OPTIMIZE PLANT POWER FACTOR | $2,835 | $3,325 | Not Implemented |
LL0139 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,787 | $435 | Implemented |
LL0133 # 08 Y:2002 | 08 | 2002 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,076 | $0 | Implemented |
LL0133 # 07 Y:2002 | 07 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $240 | $0 | Implemented |
LL0133 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $269 | $150 | Implemented |
LL0133 # 05 Y:2002 | 05 | 2002 | $379 | $0 | Not Implemented | |
LL0133 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $483 | $0 | Implemented |
LL0133 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $974 | $249 | Implemented |
LL0133 # 02 Y:2002 | 02 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,061 | $0 | Implemented |
LL0133 # 01 Y:2002 | 01 | 2002 | OPTIMIZE PLANT POWER FACTOR | $3,502 | $3,605 | Not Implemented |
LL0125 # 06 Y:2001 | 06 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,602 | $706 | Implemented |