Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
114
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0866 # 02 Y:2013 | 02 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,259 | $28,400 | Not Implemented |
OK0866 # 14 Y:2013 | 14 | 2013 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,077 | $16,000 | Implemented |
OK0866 # 11 Y:2013 | 11 | 2013 | INSULATE BARE EQUIPMENT | $232 | $280 | Implemented |
OK0866 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,260 | $28,000 | Not Implemented |
OK0866 # 13 Y:2013 | 13 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $189 | $2,098 | Not Implemented |
OK0713 # 04 Y:2005 | 04 | 2005 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $48,000 | $35 | Implemented |
OK0713 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $561 | $975 | Not Implemented |
OK0713 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,489 | $3,283 | Not Implemented |
OK0713 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,796 | $139,341 | Not Implemented |
OK0713 # 01 Y:2005 | 01 | 2005 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $81,171 | $1,436 | Implemented |
OK0713 # 03 Y:2005 | 03 | 2005 | USE COMPRESSOR AIR FILTERS | $5,346 | $35 | Implemented |
OK0713 # 02 Y:2005 | 02 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $26,495 | $85,051 | Implemented |
OK0701 # 03 Y:2005 | 03 | 2005 | INSULATE BARE EQUIPMENT | $43,354 | $1,623 | Implemented |
OK0701 # 01 Y:2005 | 01 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $11,182 | $123,420 | Implemented |
OK0701 # 06 Y:2005 | 06 | 2005 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $4,169 | $275 | Not Implemented |
OK0701 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,396 | $8,850 | Implemented |
OK0701 # 05 Y:2005 | 05 | 2005 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $19,082 | $13,500 | Not Implemented |
OK0701 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,527 | $3,807 | Not Implemented |
OK0695 # 05 Y:2004 | 05 | 2004 | COMBINE UTILITY METERS | $2,354 | $2,546 | Not Implemented |
OK0695 # 04 Y:2004 | 04 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,723 | $21,750 | Implemented |
OK0695 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,386 | $4,515 | Not Implemented |
OK0695 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,436 | $17,500 | Not Implemented |
OK0695 # 01 Y:2004 | 01 | 2004 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $35,493 | $329,564 | Not Implemented |
OK0695 # 06 Y:2004 | 06 | 2004 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $6,830 | $0 | Implemented |
OK0695 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,073 | $23,985 | Not Implemented |