Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
90
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0518 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $536 | $160 | Implemented |
NC0518 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $824 | $1,750 | Not Implemented |
NC0518 # 12 Y:2014 | 12 | 2014 | USE PHOTOCELL CONTROLS | $103 | $80 | Implemented |
NC0518 # 06 Y:2014 | 06 | 2014 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $7,321 | $15,000 | Not Implemented |
NC0518 # 05 Y:2014 | 05 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,126 | $5,000 | Not Implemented |
NC0518 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,224 | $50 | Implemented |
MI0263 # 13 Y:2014 | 13 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $409 | $173 | Implemented |
MI0263 # 12 Y:2014 | 12 | 2014 | INSULATE BARE EQUIPMENT | $708 | $280 | Not Implemented |
MI0263 # 11 Y:2014 | 11 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,317 | $80 | Implemented |
MI0263 # 01 Y:2014 | 01 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $23,147 | $3,600 | Not Implemented |
MI0263 # 02 Y:2014 | 02 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,051 | $500 | Implemented |
MI0263 # 03 Y:2014 | 03 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,762 | $28,000 | Not Implemented |
MI0263 # 04 Y:2014 | 04 | 2014 | HEAT WATER WITH EXHAUST HEAT | $6,564 | $8,859 | Not Implemented |
MI0263 # 05 Y:2014 | 05 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,131 | $4,980 | Not Implemented |
MI0263 # 06 Y:2014 | 06 | 2014 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,052 | $560 | Implemented |
MI0263 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,377 | $10,770 | Not Implemented |
MI0263 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $1,643 | $497 | Implemented |
MI0263 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,472 | $1,660 | Implemented |
MI0263 # 10 Y:2014 | 10 | 2014 | USE OPTIMUM THICKNESS INSULATION | $1,375 | $360 | Implemented |
DL0127 # 04 Y:2014 | 04 | 2014 | REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS | $1,200 | $1,800 | Not Implemented |
DL0127 # 02 Y:2014 | 02 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,800 | $2,100 | Not Implemented |
DL0127 # 11 Y:2014 | 11 | 2014 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $7,900 | $5,200 | Not Implemented |
DL0127 # 05 Y:2014 | 05 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,000 | $50 | Not Implemented |
DL0127 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $100 | Not Implemented |
DL0127 # 10 Y:2014 | 10 | 2014 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,900 | $3,200 | Not Implemented |