Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
114
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0634 # 01 Y:2002 | 01 | 2002 | INSULATE BARE EQUIPMENT | $2,496 | $823 | Implemented |
OK0634 # 02 Y:2002 | 02 | 2002 | OPERATE BOILERS ON HIGH FIRE SETTING | $2,910 | $4,125 | Implemented |
OK0634 # 03 Y:2002 | 03 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,571 | $6,000 | Not Implemented |
OK0634 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $218 | $255 | Implemented |
OK0634 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $532 | $282 | Not Implemented |
OK0634 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $992 | $1,679 | Implemented |
OK0634 # 07 Y:2002 | 07 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $216 | $2,500 | Not Implemented |
OK0634 # 08 Y:2002 | 08 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $7,297 | $1,028 | Implemented |
OK0634 # 09 Y:2002 | 09 | 2002 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $20,476 | $1,800 | Not Implemented |
OK0634 # 10 Y:2002 | 10 | 2002 | REPAIR OR REPLACE STEAM TRAPS | $33,934 | $525 | Implemented |
OK0457 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,236 | $13,720 | Not Implemented |
OK0457 # 02 Y:1995 | 02 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,691 | $64 | Implemented |
OK0457 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,741 | $4,508 | Implemented |
OK0457 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $1,344 | $3,612 | Implemented |
OK0457 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,224 | $2,077 | Implemented |
OK0457 # 06 Y:1995 | 06 | 1995 | INSULATE BARE EQUIPMENT | $882 | $2,480 | Not Implemented |
OK0457 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $199 | $240 | Implemented |
OK0457 # 08 Y:1995 | 08 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $49 | $76 | Implemented |
OK0449 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,180 | $7,639 | Not Implemented |
OK0449 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,356 | $9,402 | Not Implemented |
OK0449 # 03 Y:1994 | 03 | 1994 | INSULATE BARE EQUIPMENT | $326 | $212 | Not Implemented |
OK0449 # 04 Y:1994 | 04 | 1994 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,041 | $0 | Not Implemented |
OK0449 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,794 | $6,053 | Not Implemented |
OK0449 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,424 | $4,064 | Not Implemented |
OK0449 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,208 | $1,495 | Not Implemented |