Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,945
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0105 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $2,098 | $185 | Implemented |
LL0105 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,896 | $9,912 | Implemented |
LL0105 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,296 | $600 | Implemented |
LL0105 # 05 Y:2001 | 05 | 2001 | USE POWER DURING OFF-PEAK PERIODS | $7,014 | $24,388 | Not Implemented |
OR0382 # 01 Y:2000 | 01 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $26,817 | $900 | Implemented |
OR0382 # 02 Y:2000 | 02 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,208 | $26,491 | Implemented |
OR0382 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,194 | $2,979 | Not Implemented |
OR0382 # 04 Y:2000 | 04 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,050 | $4,653 | Not Implemented |
OR0382 # 05 Y:2000 | 05 | 2000 | OPTIMIZE PLANT POWER FACTOR | $2,241 | $6,400 | Not Implemented |
OR0382 # 06 Y:2000 | 06 | 2000 | ELIMINATE A BY-PRODUCT | $68,235 | $2,000 | Implemented |
BD0175 # 01 Y:2000 | 01 | 2000 | INSTALL OCCUPANCY SENSORS | $4,078 | $2,850 | Implemented |
BD0175 # 02 Y:2000 | 02 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,783 | $0 | Not Implemented |
BD0175 # 03 Y:2000 | 03 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,116 | $0 | Not Implemented |
BD0175 # 04 Y:2000 | 04 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $599 | $1,000 | Implemented |
BD0175 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $361 | $338 | Implemented |
BD0175 # 06 Y:2000 | 06 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $92,187 | $250,000 | Not Implemented |
BD0175 # 07 Y:2000 | 07 | 2000 | INCREASE USE OF AUTOMATION | $226,800 | $45,735 | Not Implemented |
BD0175 # 08 Y:2000 | 08 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $8,400 | $10,000 | Not Implemented |
OR0381 # 01 Y:2000 | 01 | 2000 | IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM | $27,260 | $0 | Implemented |
OR0381 # 02 Y:2000 | 02 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $699 | $300 | Implemented |
OR0381 # 03 Y:2000 | 03 | 2000 | INSULATE BARE EQUIPMENT | $540 | $345 | Not Implemented |
OR0381 # 04 Y:2000 | 04 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,850 | $8,600 | Implemented |
OR0381 # 05 Y:2000 | 05 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,096 | $390 | Implemented |
OR0381 # 06 Y:2000 | 06 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $20,970 | $40,500 | Not Implemented |
IA0260 # 01 Y:2000 | 01 | 2000 | INSTALL OCCUPANCY SENSORS | $1,666 | $1,530 | Implemented |