Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,930
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0175 # 06 Y:2000 | 06 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $92,187 | $250,000 | Not Implemented |
BD0175 # 07 Y:2000 | 07 | 2000 | INCREASE USE OF AUTOMATION | $226,800 | $45,735 | Not Implemented |
BD0175 # 08 Y:2000 | 08 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $8,400 | $10,000 | Not Implemented |
OR0381 # 01 Y:2000 | 01 | 2000 | IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM | $27,260 | $0 | Implemented |
OR0381 # 02 Y:2000 | 02 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $699 | $300 | Implemented |
OR0381 # 03 Y:2000 | 03 | 2000 | INSULATE BARE EQUIPMENT | $540 | $345 | Not Implemented |
OR0381 # 04 Y:2000 | 04 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,850 | $8,600 | Implemented |
OR0381 # 05 Y:2000 | 05 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,096 | $390 | Implemented |
OR0381 # 06 Y:2000 | 06 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $20,970 | $40,500 | Not Implemented |
IA0260 # 01 Y:2000 | 01 | 2000 | INSTALL OCCUPANCY SENSORS | $1,666 | $1,530 | Implemented |
IA0260 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,392 | $0 | Implemented |
IA0260 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $416 | $985 | Not Implemented |
IA0260 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $722 | $50 | Implemented |
IA0260 # 05 Y:2000 | 05 | 2000 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $7,513 | $14,000 | Implemented |
IA0260 # 06 Y:2000 | 06 | 2000 | MINIMIZE WATER USAGE | $243 | $44 | Implemented |
IA0260 # 07 Y:2000 | 07 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $41,184 | $90,000 | Implemented |
OR0377 # 01 Y:2000 | 01 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,486 | $0 | Not Implemented |
OR0377 # 02 Y:2000 | 02 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,345,966 | $600,000 | Not Implemented |
OR0377 # 03 Y:2000 | 03 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $97,815 | $113,670 | Not Implemented |
OR0377 # 04 Y:2000 | 04 | 2000 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $108,000 | $40,000 | Implemented |
WI0383 # 01 Y:2000 | 01 | 2000 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $41,291 | $72,000 | Not Implemented |
WI0383 # 02 Y:2000 | 02 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,801 | $20,000 | Not Implemented |
WI0383 # 03 Y:2000 | 03 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,946 | $22,500 | Implemented |
WI0383 # 04 Y:2000 | 04 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,492 | $11,550 | Implemented |
WI0383 # 05 Y:2000 | 05 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,875 | $0 | Not Implemented |