Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

909

matching recommendations
Reset
SIC 2033 Canned Fruits And Vegetables
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0384 # 09 Y:2010 09 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,199 $14,850 Not Implemented
SF0384 # 10 Y:2010 10 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,171 $37,229 Implemented
TT0038 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $49,940 $140,934 Not Implemented
TT0038 # 02 Y:2009 02 2009 REPAIR AND ELIMINATE STEAM LEAKS $21,918 $10,000 Implemented
TT0038 # 03 Y:2009 03 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,400 $4,170 Not Implemented
TT0038 # 04 Y:2009 04 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $839 $1,458 Not Implemented
TT0038 # 05 Y:2009 05 2009 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $2,893 $0 Implemented
TT0038 # 06 Y:2009 06 2009 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $33,000 $0 Not Implemented
TT0038 # 07 Y:2009 07 2009 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,036 $1,600 Implemented
TT0038 # 08 Y:2009 08 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,000 $4,900 Implemented
SD0389 # 01 Y:2006 01 2006 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $231,300 $1,500,000 Not Implemented
SD0389 # 02 Y:2006 02 2006 USE PHOTOCELL CONTROLS $846 $480 Implemented
SD0389 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $433 $2,797 Implemented
SD0389 # 04 Y:2006 04 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $601 $4,125 Not Implemented
SD0389 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $264 $1,006 Implemented
OR0510 # 01 Y:2006 01 2006 CAREFULLY CONTROL WATER LEVEL IN MASS FINISHING EQUIPMENT $61,000 $40,000 Implemented
OR0510 # 02 Y:2006 02 2006 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $15,000 $11,600 Not Implemented
OR0510 # 03 Y:2006 03 2006 RECOVER WASTE HEAT FROM EQUIPMENT $12,200 $35,000 Implemented
OR0510 # 04 Y:2006 04 2006 INSULATE BARE EQUIPMENT $11,250 $13,600 Not Implemented
OR0510 # 05 Y:2006 05 2006 INSTALL SKYLIGHTS $4,750 $12,400 Not Implemented
OR0510 # 06 Y:2006 06 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,480 $5,000 Not Implemented
OR0510 # 07 Y:2006 07 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,900 $19,200 Implemented
SF0333 # 01 Y:2006 01 2006 UTILIZE A LESS EXPENSIVE COOLING METHOD $65,964 $9,840 Not Implemented
SF0333 # 02 Y:2006 02 2006 USE COMPRESSOR AIR FILTERS $3,806 $1,200 Not Implemented
SF0333 # 03 Y:2006 03 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,592 $4,815 Not Implemented