Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
909
matching recommendationsSIC | 2033 | Canned Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0339 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,612 | $13,428 | Implemented |
LE0339 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $2,652 | $3,590 | Not Implemented |
LE0339 # 05 Y:2012 | 05 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,198 | $9,800 | Implemented |
LE0339 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,354 | $70,000 | Not Implemented |
LE0339 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,280 | $1,000 | Implemented |
LE0339 # 08 Y:2012 | 08 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,007 | $20,000 | Not Implemented |
LE0339 # 09 Y:2012 | 09 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $28,832 | $20,000 | Not Implemented |
LE0339 # 10 Y:2012 | 10 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $13,433 | $0 | Implemented |
LE0339 # 11 Y:2012 | 11 | 2012 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $59,246 | $10,500 | Not Implemented |
SF0405 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,795 | $1,200 | Implemented |
SF0405 # 02 Y:2012 | 02 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $76,949 | $36,149 | Implemented |
SF0405 # 03 Y:2012 | 03 | 2012 | INCREASE AMOUNT OF CONDENSATE RETURNED | $139,563 | $85,532 | Implemented |
SF0405 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,933 | $21,797 | Not Implemented |
SF0405 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $38,824 | $39,132 | Not Implemented |
SF0405 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,152 | $11,614 | Not Implemented |
SF0405 # 07 Y:2012 | 07 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $52,595 | $93,960 | Not Implemented |
SF0405 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $3,761 | $9,004 | Implemented |
SF0405 # 09 Y:2012 | 09 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $112,997 | $524,700 | Not Implemented |
SF0405 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,215 | $62,332 | Implemented |
SF0405 # 11 Y:2012 | 11 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,005 | $6,397 | Not Implemented |
MI0209 # 01 Y:2011 | 01 | 2011 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $4,297,734 | $3,000,000 | Implemented |
MI0209 # 02 Y:2011 | 02 | 2011 | HEAT WATER WITH EXHAUST HEAT | $240,185 | $30,000 | Not Implemented |
MI0209 # 03 Y:2011 | 03 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $192,436 | $36,000 | Not Implemented |
MI0209 # 04 Y:2011 | 04 | 2011 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $132,137 | $500,000 | Implemented |
MI0209 # 05 Y:2011 | 05 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $112,996 | $1,950 | Implemented |