Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

175

matching recommendations
Reset
SIC 2034 Dehydrated Fruits, Vegetables, Soups
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0148 # 05 Y:2002 05 2002 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $9,006 $3,700 Implemented
SU0148 # 06 Y:2002 06 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,438 $320 Not Implemented
SU0148 # 07 Y:2002 07 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $105 $0 Implemented
SU0148 # 08 Y:2002 08 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $70 $60 Implemented
OR0377 # 01 Y:2000 01 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,486 $0 Not Implemented
OR0377 # 02 Y:2000 02 2000 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $1,345,966 $600,000 Not Implemented
OR0377 # 03 Y:2000 03 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $97,815 $113,670 Not Implemented
OR0377 # 04 Y:2000 04 2000 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $108,000 $40,000 Implemented
SF0167 # 01 Y:1999 01 1999 REPAIR AND ELIMINATE STEAM LEAKS $9,860 $175 Not Implemented
SF0167 # 02 Y:1999 02 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $2,924 $0 Not Implemented
SF0167 # 03 Y:1999 03 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,516 $1,500 Not Implemented
SF0167 # 04 Y:1999 04 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $9,607 $5,759 Not Implemented
SF0167 # 05 Y:1999 05 1999 INSTALL OCCUPANCY SENSORS $1,796 $1,080 Not Implemented
SF0167 # 06 Y:1999 06 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,077 $4,185 Not Implemented
SF0167 # 07 Y:1999 07 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $5,150 $8,430 Not Implemented
SF0167 # 08 Y:1999 08 1999 INSULATE FEEDWATER TANK $601 $1,327 Not Implemented
SF0167 # 09 Y:1999 09 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,353 $30,890 Not Implemented
NV0090 # 01 Y:1997 01 1997 INSULATE BARE EQUIPMENT $9,086 $58,500 Implemented
NV0090 # 02 Y:1997 02 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $124 $0 Implemented
CO0387 # 01 Y:1997 01 1997 RECOVER WASTE HEAT FROM EQUIPMENT $6,360 $8,400 Implemented
CO0387 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,130 $1,500 Implemented
CO0387 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $289 $288 Implemented
CO0387 # 04 Y:1997 04 1997 REPAIR AND ELIMINATE STEAM LEAKS $670 $140 Implemented
CO0387 # 05 Y:1997 05 1997 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $380 $430 Implemented
CO0387 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $220 $290 Implemented