IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

421

matching recommendations
Reset
SIC 2035 Pickles, Sauces, And Salad Dressings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0598 # 02 Y:2017 02 2017 INSTALL OCCUPANCY SENSORS $165 $547 Implemented
NC0598 # 04 Y:2017 04 2017 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,276 $1,050 Not Implemented
NC0598 # 05 Y:2017 05 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $932 $100 Implemented
NC0598 # 03 Y:2017 03 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,199 $50 Not Implemented
DL0151 # 08 Y:2015 08 2015 MINIMIZE WATER USAGE $80,640 $200,250 Not Implemented
DL0151 # 07 Y:2015 07 2015 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,970 $4,480 Not Implemented
DL0151 # 06 Y:2015 06 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,550 $14,400 Not Implemented
DL0151 # 05 Y:2015 05 2015 UPGRADE CONTROLS ON COMPRESSORS $7,730 $11,520 Not Implemented
DL0151 # 04 Y:2015 04 2015 OPERATE BOILERS ON HIGH FIRE SETTING $10,860 $4,610 Not Implemented
DL0151 # 03 Y:2015 03 2015 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $60,250 $20,000 Not Implemented
DL0151 # 02 Y:2015 02 2015 MINIMIZE OVERFLOWS BY INSTALLING LEVEL CONTROLS $37,680 $12,400 Not Implemented
DL0151 # 01 Y:2015 01 2015 USE CORRECT SIZE STEAM TRAPS $12,870 $2,380 Not Implemented
TT0125 # 04 Y:2014 04 2014 INSTALL OCCUPANCY SENSORS $148 $240 Not Implemented
TT0125 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,282 $550 Not Implemented
TT0125 # 05 Y:2014 05 2014 INSTALL OCCUPANCY SENSORS $388 $360 Not Implemented
TT0125 # 06 Y:2014 06 2014 INSTALL OCCUPANCY SENSORS $724 $720 Not Implemented
TT0125 # 02 Y:2014 02 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $764 $505 Not Implemented
TT0125 # 03 Y:2014 03 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $724 $1,000 Not Implemented
TT0125 # 01 Y:2014 01 2014 REPAIR AND ELIMINATE STEAM LEAKS $11,367 $1,500 Implemented
MA0712 # 04 Y:2013 04 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,440 $4,200 Not Implemented
MA0712 # 08 Y:2013 08 2013 INSULATE BARE EQUIPMENT $323 $750 Implemented
MA0712 # 06 Y:2013 06 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $853 $2,930 Not Implemented
MA0712 # 07 Y:2013 07 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $827 $1,200 Implemented
MA0712 # 05 Y:2013 05 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $938 $2,930 Not Implemented
MA0712 # 01 Y:2013 01 2013 USE RADIANT HEATER FOR SPOT HEATING $13,420 $65,327 Implemented