Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,021

matching recommendations
Reset
SIC 204 Grain Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0064 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $907 $1,038 Implemented
SD0064 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,679 $5,291 Implemented
SD0064 # 04 Y:1993 04 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $795 $600 Implemented
SD0064 # 05 Y:1993 05 1993 KEEP BOILER TUBES CLEAN $4,163 $2,000 Implemented
SD0064 # 06 Y:1993 06 1993 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,928 $674 Implemented
SD0064 # 10 Y:1993 10 1993 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $12,485 $15,690 Implemented
SD0064 # 11 Y:1993 11 1993 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $1,874 $1,256 Implemented
SD0064 # 12 Y:1993 12 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,459 $120 Implemented
SD0064 # 13 Y:1993 13 1993 INSTALL SET-BACK TIMERS $174 $100 Implemented
SD0064 # 14 Y:1993 14 1993 USE PHOTOCELL CONTROLS $1,543 $575 Implemented
SD0064 # 15 Y:1993 15 1993 INSTALL SET-BACK TIMERS $400 $760 Implemented
SD0064 # 16 Y:1993 16 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $293 $24 Implemented
ND0166 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,734 $1,418 Implemented
ND0166 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,400 $1,500 Implemented
ND0166 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $651 $125 Implemented
ND0166 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $93 $20 Implemented
IA0038 # 03 Y:1992 03 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,907 $150 Implemented
AM0156 # 02 Y:1992 02 1992 OPTIMIZE PLANT POWER FACTOR $10,125 $1,500 Implemented
AM0156 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,117 $3,200 Implemented
AM0156 # 04 Y:1992 04 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,040 $860 Implemented
AM0156 # 05 Y:1992 05 1992 INSTALL SET-BACK TIMERS $2,900 $0 Implemented
OK0385 # 01 Y:1992 01 1992 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $265 $280 Implemented
OK0385 # 02 Y:1992 02 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,839 $608 Implemented
OK0385 # 03 Y:1992 03 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $705 $2,000 Implemented
OK0385 # 04 Y:1992 04 1992 REPAIR AND ELIMINATE STEAM LEAKS $980 $0 Implemented