Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
67
matching recommendationsSIC | 204 | Grain Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0587 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $891 | $24 | n/a |
OK0587 # 04 Y:1999 | 04 | 1999 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $3,795 | $0 | n/a |
OK0587 # 05 Y:1999 | 05 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,193 | $3,150 | n/a |
OK0587 # 03 Y:1999 | 03 | 1999 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $7,398 | $31,705 | n/a |
OK0587 # 08 Y:1999 | 08 | 1999 | INSULATE BARE EQUIPMENT | $250 | $525 | n/a |
OK0587 # 07 Y:1999 | 07 | 1999 | INSULATE BARE EQUIPMENT | $252 | $1,028 | n/a |
OK0587 # 02 Y:1999 | 02 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,905 | $0 | n/a |
OK0587 # 01 Y:1999 | 01 | 1999 | INSTALL SYSTEM TO COLLECT SCRAP | $20,078 | $2,250 | n/a |
CO0451 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20 | $0 | Not Implemented |
CO0451 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $190 | $320 | Implemented |
CO0451 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $220 | $20 | Implemented |
CO0451 # 02 Y:1999 | 02 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,080 | $4,000 | Implemented |
CO0451 # 01 Y:1999 | 01 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,190 | $6,250 | Not Implemented |
ME0273 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,750 | $4,260 | n/a |
ME0273 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,815 | $5,192 | n/a |
ME0273 # 08 Y:1999 | 08 | 1999 | ELIMINATE/REDUCE AN OPERATION | $1,716 | $612 | n/a |
ME0273 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $309 | $100 | n/a |
ME0273 # 07 Y:1999 | 07 | 1999 | REDUCE SCRAP PRODUCTION | $13,050 | $22,253 | n/a |
ME0273 # 03 Y:1999 | 03 | 1999 | USE SOLAR HEAT FOR HEAT | $1,220 | $5,472 | n/a |
ME0273 # 04 Y:1999 | 04 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $421 | $0 | n/a |
ME0273 # 06 Y:1999 | 06 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $23,318 | $212,393 | n/a |
ND0324 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,051 | $250 | Implemented |
ND0324 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,258 | $30,000 | Implemented |
ND0324 # 04 Y:1999 | 04 | 1999 | DEVELOP A REPAIR/REPLACE POLICY | $52,604 | $41,503 | Not Implemented |
ND0324 # 06 Y:1999 | 06 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $-252 | $0 | Not Implemented |