IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,411

matching recommendations
Reset
SIC 205 Bakery Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0185 # 08 Y:1996 08 1996 INSULATE BARE EQUIPMENT $660 $1,000 Implemented
ME0185 # 09 Y:1996 09 1996 CLOSE OFF UNNEEDED STEAM LINES $812 $1,850 Implemented
TN0583 # 01 Y:1996 01 1996 MAKE A NEW BY-PRODUCT $723,960 $390,800 Not Implemented
TN0583 # 02 Y:1996 02 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $9,110 $16,600 Not Implemented
TN0583 # 03 Y:1996 03 1996 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $1,824 $3,000 Not Implemented
TN0583 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $715 $260 Implemented
TN0583 # 05 Y:1996 05 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $329 $300 Not Implemented
TN0583 # 06 Y:1996 06 1996 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $189 $236 Not Implemented
HO0128 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $574 $827 Implemented
HO0128 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $391 $528 Implemented
HO0128 # 03 Y:1996 03 1996 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,380 $740 Not Implemented
HO0128 # 04 Y:1996 04 1996 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,000 $1,900 Implemented
HO0128 # 05 Y:1996 05 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $1,200 $100 Implemented
SF0082 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,889 $1,543 Implemented
SF0082 # 02 Y:1996 02 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,109 $1,393 Implemented
SF0082 # 03 Y:1996 03 1996 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $709 $710 Implemented
SF0082 # 04 Y:1996 04 1996 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,170 $50 Implemented
SF0082 # 05 Y:1996 05 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,590 $6,792 Implemented
SF0082 # 06 Y:1996 06 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,734 $0 Implemented
SF0082 # 07 Y:1996 07 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $4,221 $0 Implemented
SF0082 # 08 Y:1996 08 1996 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $3,473 $1,625 Implemented
SF0082 # 09 Y:1996 09 1996 METER WASTE WATER $7,225 $4,500 Not Implemented
UL0148 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,550 $4,024 Implemented
UL0148 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,644 $3,850 Implemented
UL0148 # 03 Y:1996 03 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,558 $2,000 Implemented