IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

76

matching recommendations
Reset
SIC 2051 Bread, Cake, And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0791 # 09 Y:2010 09 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $2,130 $1,244 Not Implemented
OK0787 # 08 Y:2010 08 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $17,321 $9,900 Not Implemented
OK0787 # 07 Y:2010 07 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,451 $16,000 Implemented
OK0787 # 06 Y:2010 06 2010 REPLACE BOILER $13,921 $51,278 Not Implemented
OK0787 # 05 Y:2010 05 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $176 $86 Implemented
OK0787 # 04 Y:2010 04 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,813 $22,000 n/a
OK0787 # 03 Y:2010 03 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,663 $20,689 Not Implemented
OK0787 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,288 $7,168 Implemented
OK0787 # 01 Y:2010 01 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,335 $47,872 Not Implemented
OK0546 # 06 Y:1998 06 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,273 $2,460 Implemented
OK0546 # 10 Y:1998 10 1998 INSULATE BARE EQUIPMENT $176 $542 Implemented
OK0546 # 09 Y:1998 09 1998 INSTALL OCCUPANCY SENSORS $327 $660 Not Implemented
OK0546 # 08 Y:1998 08 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,395 $4,626 Not Implemented
OK0546 # 07 Y:1998 07 1998 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $1,398 $500 Implemented
OK0546 # 05 Y:1998 05 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,438 $5,916 Implemented
OK0546 # 04 Y:1998 04 1998 PREHEAT COMBUSTION AIR WITH WASTE HEAT $5,243 $15,100 Not Implemented
OK0546 # 03 Y:1998 03 1998 PURCHASE MATERIAL FROM SUPPLIER IN CUSTOMIZED PACKAGING $6,240 $0 Not Implemented
OK0546 # 02 Y:1998 02 1998 INSTALL SOLID WASTE INCINERATOR FOR HEAT $10,400 $7,900 Implemented
OK0546 # 01 Y:1998 01 1998 MOVE PRODUCT USING MECHANICAL MEANS $15,431 $20,000 Not Implemented
OK0536 # 01 Y:1997 01 1997 INSTALL OCCUPANCY SENSORS $3,824 $1,549 Not Implemented
OK0536 # 07 Y:1997 07 1997 USE LESS WASTEFUL PACKAGING $4,440 $0 Not Implemented
OK0536 # 06 Y:1997 06 1997 METER WASTE WATER $75,704 $0 Implemented
OK0536 # 05 Y:1997 05 1997 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $825 $99 Not Implemented
OK0536 # 04 Y:1997 04 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $365 $0 Implemented
OK0536 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $332 $689 Not Implemented