Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 208 | Beverages |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0907 # 09 Y:2015 | 09 | 2015 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,429 | $960 | Implemented |
OK0907 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $1,237 | $706 | Implemented |
OK0907 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,448 | $1,250 | Implemented |
OK0907 # 11 Y:2015 | 11 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,466 | $0 | Implemented |
OK0907 # 12 Y:2015 | 12 | 2015 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,510 | $3,052 | Implemented |
OK0907 # 02 Y:2015 | 02 | 2015 | INSTALL OCCUPANCY SENSORS | $1,302 | $332 | Implemented |
OK0907 # 07 Y:2015 | 07 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,403 | $800 | Implemented |
KU0514 # 01 Y:1999 | 01 | 1999 | USE OPTIMUM TEMPERATURE | $25,150 | $9,360 | Implemented |
KU0514 # 07 Y:1999 | 07 | 1999 | MINIMIZE WATER USAGE | $12,240 | $22,300 | Implemented |
KU0514 # 10 Y:1999 | 10 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $106,720 | $288,000 | Implemented |
KU0514 # 06 Y:1999 | 06 | 1999 | INSULATE BARE EQUIPMENT | $1,120 | $860 | Implemented |
KU0514 # 03 Y:1999 | 03 | 1999 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $2,250 | $280 | Implemented |
KU0514 # 09 Y:1999 | 09 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $490 | $260 | Implemented |
KU0180 # 09 Y:1985 | 09 | 1985 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $206 | $700 | Implemented |
KU0180 # 03 Y:1985 | 03 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,326 | $0 | Implemented |
KU0180 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $3,940 | $400 | Implemented |
KU0178 # 03 Y:1985 | 03 | 1985 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,185 | $300 | Implemented |
KU0178 # 06 Y:1985 | 06 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,397 | $2,000 | Implemented |
KU0178 # 07 Y:1985 | 07 | 1985 | INSULATE BARE EQUIPMENT | $2,651 | $1,952 | Implemented |
KU0178 # 11 Y:1985 | 11 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $423 | $50 | Implemented |
KU0178 # 13 Y:1985 | 13 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $360 | $120 | Implemented |
KU0178 # 15 Y:1985 | 15 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $498 | $200 | Implemented |
KU0178 # 16 Y:1985 | 16 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $446 | $0 | Implemented |
KU0178 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,915 | $3,542 | Implemented |
KU0178 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $14,225 | $10 | Implemented |