Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
133
matching recommendationsSIC | 208 | Beverages |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0146 # 10 Y:2019 | 10 | 2019 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,482 | $1,000 | Not Implemented |
UU0146 # 09 Y:2019 | 09 | 2019 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $97 | $75 | Implemented |
UU0146 # 01 Y:2019 | 01 | 2019 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $37,500 | $225,000 | Not Implemented |
UU0146 # 08 Y:2019 | 08 | 2019 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $231 | $1,100 | Not Implemented |
CO0688 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,490 | $10,380 | Not Implemented |
CO0688 # 04 Y:2014 | 04 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $610 | $2,270 | Not Implemented |
CO0688 # 01 Y:2014 | 01 | 2014 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,830 | $8,050 | Not Implemented |
CO0688 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,160 | $3,140 | Not Implemented |
CO0688 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,390 | $1,500 | Implemented |
CO0677 # 01 Y:2013 | 01 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $3,450 | $14,200 | Not Implemented |
CO0677 # 02 Y:2013 | 02 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,660 | $1,620 | Implemented |
CO0677 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $520 | $0 | Implemented |
CO0677 # 04 Y:2013 | 04 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $430 | $2,450 | Not Implemented |
CO0677 # 05 Y:2013 | 05 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,810 | $0 | Implemented |
CO0677 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $640 | $3,450 | Implemented |
CO0596 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,120 | $9,260 | Implemented |
CO0596 # 07 Y:2006 | 07 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,100 | $2,950 | Not Implemented |
CO0596 # 04 Y:2006 | 04 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,810 | $1,000 | Implemented |
CO0596 # 05 Y:2006 | 05 | 2006 | ADD AREA LIGHTING SWITCHES | $2,410 | $100 | Not Implemented |
CO0596 # 01 Y:2006 | 01 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $244 | $1,008 | Implemented |
CO0596 # 03 Y:2006 | 03 | 2006 | INCREASE EFFICIENCY OF TRUCKS | $5,740 | $0 | Implemented |
CO0596 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,270 | $33,120 | Implemented |
CO0596 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $910 | $5,740 | Implemented |
CO0531 # 08 Y:2003 | 08 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $1,280 | $220 | Not Implemented |