Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
596
matching recommendationsSIC | 2082 | Malt Beverages |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0146 # 07 Y:2019 | 07 | 2019 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $367 | $1,200 | Not Implemented |
UU0146 # 08 Y:2019 | 08 | 2019 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $231 | $1,100 | Not Implemented |
UU0146 # 09 Y:2019 | 09 | 2019 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $97 | $75 | Implemented |
UU0146 # 10 Y:2019 | 10 | 2019 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,482 | $1,000 | Not Implemented |
LS1815 # 01 Y:2018 | 01 | 2018 | PAY UTILITY BILLS ON TIME | $459 | $25 | Implemented |
LS1815 # 02 Y:2018 | 02 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,369 | $350 | Implemented |
LS1815 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $73 | $25 | Implemented |
LS1815 # 04 Y:2018 | 04 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $146 | $125 | Implemented |
LS1815 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $15 | $100 | Implemented |
LS1815 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,427 | $3,000 | Implemented |
LS1815 # 07 Y:2018 | 07 | 2018 | USE PHOTOCELL CONTROLS | $88 | $225 | Not Implemented |
LS1815 # 08 Y:2018 | 08 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $261 | $788 | Not Implemented |
LS1810 # 01 Y:2018 | 01 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $358 | $25 | Not Implemented |
LS1810 # 02 Y:2018 | 02 | 2018 | INSTALL / REPAIR INSULATION ON STEAM LINES | $880 | $340 | Implemented |
LS1810 # 03 Y:2018 | 03 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $650 | $650 | Not Implemented |
LS1810 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $986 | $1,088 | Implemented |
LS1810 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $37 | $55 | Not Implemented |
LS1810 # 06 Y:2018 | 06 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $764 | $1,800 | Implemented |
UD0983 # 01 Y:2018 | 01 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $390 | $50 | Not Implemented |
UD0983 # 02 Y:2018 | 02 | 2018 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $13,719 | $2,500 | Not Implemented |
UD0983 # 03 Y:2018 | 03 | 2018 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,019 | $4,500 | Not Implemented |
UD0983 # 04 Y:2018 | 04 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,393 | $6,000 | Not Implemented |
UD0983 # 05 Y:2018 | 05 | 2018 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,115 | $0 | Implemented |
UD0983 # 06 Y:2018 | 06 | 2018 | USE OPTIMUM TEMPERATURE | $836 | $0 | Not Implemented |
UD0983 # 07 Y:2018 | 07 | 2018 | INSTALL / REPAIR INSULATION ON STEAM LINES | $819 | $1,100 | Implemented |