Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

233

matching recommendations
Reset
SIC 2086 Bottled And Canned Soft Drinks
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0291 # 10 Y:2002 10 2002 SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM $16,158 $0 Not Implemented
UF0291 # 11 Y:2002 11 2002 MOVE BOILER TO MORE EFFICIENT LOCATION $4,387 $0 Implemented
UF0291 # 12 Y:2002 12 2002 METER WASTE WATER $4,133 $1,500 Implemented
UF0291 # 13 Y:2002 13 2002 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $2,309 $8,820 Not Implemented
UF0291 # 14 Y:2002 14 2002 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME $12,120 $16,900 Not Implemented
MI0014 # 01 Y:2001 01 2001 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $96,925 $990 Not Implemented
MI0014 # 02 Y:2001 02 2001 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $45,630 $0 Not Implemented
MI0014 # 03 Y:2001 03 2001 MODIFY STARTUP/SHUTDOWN TIMES $9,086 $867 Implemented
MI0014 # 04 Y:2001 04 2001 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $5,618 $5,000 Not Implemented
MI0014 # 05 Y:2001 05 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $661 $5 Implemented
MI0014 # 06 Y:2001 06 2001 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,056 $20 Implemented
MI0014 # 07 Y:2001 07 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,454 $80 Implemented
UF0268 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $198 $211 n/a
UF0268 # 02 Y:2001 02 2001 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $7,078 $50 n/a
UF0268 # 03 Y:2001 03 2001 INSTALL OCCUPANCY SENSORS $580 $311 n/a
UF0268 # 04 Y:2001 04 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,077 $165 n/a
UF0268 # 05 Y:2001 05 2001 OPTIMIZE PLANT POWER FACTOR $2,813 $4,519 n/a
UF0268 # 06 Y:2001 06 2001 PAY UTILITY BILLS ON TIME $69 $5,256 n/a
UF0268 # 07 Y:2001 07 2001 INSTALL SENSORS TO DETECT DEFECTS $12,480 $0 n/a
UF0161 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,316 $7,288 Not Implemented
UF0161 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $491 $6,951 Implemented
UF0161 # 03 Y:1996 03 1996 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $546 $500 Not Implemented
UF0161 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,132 $1,000 Implemented
UF0161 # 05 Y:1996 05 1996 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,171 $7,500 Not Implemented
UF0161 # 06 Y:1996 06 1996 TREAT AND REUSE RINSE WATERS $816 $865 Not Implemented