Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 209 | Misc. Food And Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1070 # 02 Y:2024 | 02 | 2024 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $22,179 | $2,000 | Implemented |
UD1070 # 01 Y:2024 | 01 | 2024 | REPAIR AND ELIMINATE STEAM LEAKS | $5,413 | $1,000 | Implemented |
UD0877 # 09 Y:2013 | 09 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $685 | $2,000 | Implemented |
UD0877 # 08 Y:2013 | 08 | 2013 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $61,182 | $25,000 | Implemented |
UD0877 # 06 Y:2013 | 06 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,095 | $0 | Implemented |
UD0877 # 02 Y:2013 | 02 | 2013 | METER WASTE WATER | $18,660 | $1,000 | Implemented |
UD0877 # 01 Y:2013 | 01 | 2013 | ELIMINATE THIRD SHIFT | $75,782 | $0 | Implemented |
UD0592 # 04 Y:2000 | 04 | 2000 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $5,506 | $2,000 | Implemented |
UD0592 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $8,655 | $8,000 | Implemented |
UD0505 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,110 | $6,000 | Implemented |
UD0505 # 07 Y:1996 | 07 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,640 | $0 | Implemented |
UD0505 # 06 Y:1996 | 06 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,448 | $1,000 | Implemented |
UD0505 # 04 Y:1996 | 04 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,221 | $500 | Implemented |
UD0505 # 03 Y:1996 | 03 | 1996 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $8,648 | $4,000 | Implemented |
UD0505 # 02 Y:1996 | 02 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,214 | $0 | Implemented |
UD0505 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $12,351 | $9,000 | Implemented |
UD0284 # 06 Y:1989 | 06 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,404 | $2,300 | Implemented |
UD0284 # 05 Y:1989 | 05 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,648 | $0 | Implemented |
UD0284 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,210 | $0 | Implemented |
UD0284 # 02 Y:1989 | 02 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,285 | $0 | Implemented |
UD0284 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $38,356 | $20,000 | Implemented |
UD0166 # 01 Y:1985 | 01 | 1985 | RECOVER AND REUSE COOLING WATER | $10,849 | $7,160 | Implemented |
UD0166 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,258 | $50,000 | Implemented |
UD0166 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,600 | $40,000 | Implemented |