Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
94
matching recommendationsSIC | 209 | Misc. Food And Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0124 # 04 Y:1998 | 04 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $7,805 | $4,595 | Not Implemented |
OD0124 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,935 | $6,012 | Implemented |
OD0124 # 02 Y:1998 | 02 | 1998 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $437 | $1,290 | Not Implemented |
OD0124 # 03 Y:1998 | 03 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,225 | $5,625 | Not Implemented |
OD0048 # 02 Y:1996 | 02 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,112 | $1,077 | Not Implemented |
OD0048 # 05 Y:1996 | 05 | 1996 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,538 | $1,332 | Not Implemented |
OD0048 # 06 Y:1996 | 06 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $7,493 | $1,072 | Not Implemented |
OD0048 # 01 Y:1996 | 01 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,211 | $13,391 | Not Implemented |
OD0048 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,780 | $3,754 | Not Implemented |
OD0048 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,515 | $9,800 | Not Implemented |
OD0047 # 06 Y:1996 | 06 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $8,250 | $300 | Not Implemented |
OD0047 # 05 Y:1996 | 05 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,534 | $0 | Not Implemented |
OD0047 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $3,807 | $802 | Not Implemented |
OD0047 # 03 Y:1996 | 03 | 1996 | REPAIR AND ELIMINATE STEAM LEAKS | $477 | $700 | Implemented |
OD0047 # 02 Y:1996 | 02 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $765 | $500 | Not Implemented |
OD0047 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,124 | $2,025 | Implemented |
OD0034 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,560 | $14,940 | Implemented |
OD0034 # 01 Y:1995 | 01 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $72,922 | $168,455 | Not Implemented |
OD0034 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,752 | $83 | Implemented |
OD0034 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,941 | $3,025 | Implemented |
OD0034 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,517 | $500 | Not Implemented |
OD0020 # 01 Y:1995 | 01 | 1995 | REPLACE BOILER | $14,400 | $20,000 | Not Implemented |
OD0020 # 02 Y:1995 | 02 | 1995 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $7,452 | $0 | Not Implemented |
OD0020 # 03 Y:1995 | 03 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,543 | $200 | Implemented |
OD0020 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $384 | $600 | Not Implemented |