Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
487
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0471 # 01 Y:2000 | 01 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $7,546 | $18,500 | Not Implemented |
MA0471 # 02 Y:2000 | 02 | 2000 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $3,105 | $11,000 | Not Implemented |
MA0471 # 03 Y:2000 | 03 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,804 | $7,200 | Not Implemented |
MA0471 # 04 Y:2000 | 04 | 2000 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $1,548 | $4,000 | Not Implemented |
MA0471 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,361 | $19,740 | Not Implemented |
MA0471 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $114 | $120 | Implemented |
OD0164 # 01 Y:2000 | 01 | 2000 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $4,040 | $0 | Not Implemented |
OD0164 # 02 Y:2000 | 02 | 2000 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,088 | $1,000 | Not Implemented |
OD0164 # 03 Y:2000 | 03 | 2000 | METER WASTE WATER | $1,000 | $6,000 | Not Implemented |
OD0164 # 04 Y:2000 | 04 | 2000 | METER WASTE WATER | $3,200 | $6,000 | Not Implemented |
OD0164 # 05 Y:2000 | 05 | 2000 | PAY UTILITY BILLS ON TIME | $209 | $0 | Not Implemented |
OD0163 # 01 Y:2000 | 01 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,221 | $1,000 | Not Implemented |
OD0163 # 02 Y:2000 | 02 | 2000 | USE SYNTHETIC LUBRICANT | $372 | $67 | Implemented |
OD0163 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $50 | $95 | Not Implemented |
OD0163 # 04 Y:2000 | 04 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $104 | $285 | Not Implemented |
MS0162 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $575 | $371 | Not Implemented |
MS0162 # 02 Y:2000 | 02 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $453 | $472 | Not Implemented |
MS0162 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $429 | $158 | Implemented |
MS0162 # 04 Y:2000 | 04 | 2000 | HEAT WATER WITH EXHAUST HEAT | $4,758 | $13,860 | Not Implemented |
MS0162 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,175 | $2,450 | Implemented |
MS0162 # 06 Y:2000 | 06 | 2000 | APPLY FOR INVESTMENT INCENTIVES | $926 | $25 | Not Implemented |
ME0289 # 01 Y:2000 | 01 | 2000 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $66,856 | $175,000 | Not Implemented |
ME0289 # 02 Y:2000 | 02 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,387 | $3,165 | Implemented |
ME0289 # 03 Y:2000 | 03 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,100 | $6,600 | Not Implemented |
ME0289 # 04 Y:2000 | 04 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,671 | $5,350 | Not Implemented |