Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
487
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0289 # 05 Y:2000 | 05 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,507 | $2,400 | Implemented |
ME0289 # 06 Y:2000 | 06 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $300 | $463 | Not Implemented |
OD0156 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,988 | $7,743 | Implemented |
OD0156 # 02 Y:2000 | 02 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,143 | $0 | Not Implemented |
OD0156 # 03 Y:2000 | 03 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $148 | $209 | Implemented |
OD0156 # 04 Y:2000 | 04 | 2000 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $581 | $0 | Not Implemented |
OD0156 # 05 Y:2000 | 05 | 2000 | MINIMIZE WATER USAGE | $26,775 | $6,000 | Not Implemented |
OD0150 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,354 | $9,564 | Not Implemented |
OD0150 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $370 | $400 | Not Implemented |
OD0150 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $402 | $20 | Not Implemented |
OD0150 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $611 | $3,660 | Not Implemented |
OD0150 # 05 Y:1999 | 05 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $779 | $0 | Not Implemented |
OD0151 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $855 | $487 | Not Implemented |
OD0151 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $45 | $95 | Not Implemented |
OD0151 # 03 Y:2000 | 03 | 2000 | USE PHOTOCELL CONTROLS | $194 | $100 | Not Implemented |
OD0151 # 04 Y:2000 | 04 | 2000 | INSTALL SKYLIGHTS | $106 | $180 | Not Implemented |
OD0151 # 05 Y:2000 | 05 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,229 | $1,815 | Not Implemented |
OD0151 # 06 Y:2000 | 06 | 2000 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $180 | $725 | Not Implemented |
OR0359 # 01 Y:1999 | 01 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $80,000 | $95,000 | Not Implemented |
OR0359 # 02 Y:1999 | 02 | 1999 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,013 | $0 | Implemented |
OR0359 # 03 Y:1999 | 03 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,648 | $9,500 | Not Implemented |
OR0359 # 04 Y:1999 | 04 | 1999 | OPTIMIZE PLANT POWER FACTOR | $786 | $2,200 | Not Implemented |
OR0359 # 05 Y:1999 | 05 | 1999 | COMBINE UTILITY METERS | $1,851 | $10,000 | Not Implemented |
OR0358 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $0 | $3,600 | Not Implemented |
OR0358 # 02 Y:1999 | 02 | 1999 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $2,574 | $12,750 | Not Implemented |