Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

487

matching recommendations
Reset
SIC 2092 Fresh Or Frozen Prepared Fish
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0289 # 05 Y:2000 05 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $9,507 $2,400 Implemented
ME0289 # 06 Y:2000 06 2000 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $300 $463 Not Implemented
OD0156 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,988 $7,743 Implemented
OD0156 # 02 Y:2000 02 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $6,143 $0 Not Implemented
OD0156 # 03 Y:2000 03 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $148 $209 Implemented
OD0156 # 04 Y:2000 04 2000 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $581 $0 Not Implemented
OD0156 # 05 Y:2000 05 2000 MINIMIZE WATER USAGE $26,775 $6,000 Not Implemented
OD0150 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,354 $9,564 Not Implemented
OD0150 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $370 $400 Not Implemented
OD0150 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $402 $20 Not Implemented
OD0150 # 04 Y:1999 04 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $611 $3,660 Not Implemented
OD0150 # 05 Y:1999 05 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $779 $0 Not Implemented
OD0151 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $855 $487 Not Implemented
OD0151 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $45 $95 Not Implemented
OD0151 # 03 Y:2000 03 2000 USE PHOTOCELL CONTROLS $194 $100 Not Implemented
OD0151 # 04 Y:2000 04 2000 INSTALL SKYLIGHTS $106 $180 Not Implemented
OD0151 # 05 Y:2000 05 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,229 $1,815 Not Implemented
OD0151 # 06 Y:2000 06 2000 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $180 $725 Not Implemented
OR0359 # 01 Y:1999 01 1999 INSTALL AUTOMATIC PACKING EQUIPMENT $80,000 $95,000 Not Implemented
OR0359 # 02 Y:1999 02 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,013 $0 Implemented
OR0359 # 03 Y:1999 03 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,648 $9,500 Not Implemented
OR0359 # 04 Y:1999 04 1999 OPTIMIZE PLANT POWER FACTOR $786 $2,200 Not Implemented
OR0359 # 05 Y:1999 05 1999 COMBINE UTILITY METERS $1,851 $10,000 Not Implemented
OR0358 # 01 Y:1999 01 1999 OPTIMIZE PLANT POWER FACTOR $0 $3,600 Not Implemented
OR0358 # 02 Y:1999 02 1999 MODERATE COOLING TOWER OUTLET TEMPERATURE $2,574 $12,750 Not Implemented