Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,498
matching recommendationsSIC | 2099 | Food Preparations, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0287 # 03 Y:1986 | 03 | 1986 | INSULATE BARE EQUIPMENT | $1,458 | $398 | Not Implemented |
TN0287 # 04 Y:1986 | 04 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,277 | $750 | Implemented |
TN0287 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,422 | $820 | Not Implemented |
TN0287 # 06 Y:1986 | 06 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $288 | $1,000 | Implemented |
TN0287 # 07 Y:1986 | 07 | 1986 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $159 | $35 | Implemented |
TN0287 # 08 Y:1986 | 08 | 1986 | INSTALL SET-BACK TIMERS | $531 | $0 | Not Implemented |
TN0287 # 09 Y:1986 | 09 | 1986 | USE MINIMUM STEAM OPERATING PRESSURE | $82 | $0 | Implemented |
AT0038 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33 | $32 | Not Implemented |
AT0038 # 02 Y:1986 | 02 | 1986 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,018 | $4,000 | Not Implemented |
AT0038 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $48 | $18 | Not Implemented |
AT0038 # 04 Y:1986 | 04 | 1986 | INSULATE BARE EQUIPMENT | $140 | $150 | Not Implemented |
AT0038 # 05 Y:1986 | 05 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $95 | $0 | Not Implemented |
AT0038 # 06 Y:1986 | 06 | 1986 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,567 | $985 | Not Implemented |
CO0059 # 01 Y:1986 | 01 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $34,952 | $300 | Implemented |
CO0059 # 02 Y:1986 | 02 | 1986 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $6,532 | $12,000 | Not Implemented |
CO0059 # 03 Y:1986 | 03 | 1986 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,339 | $800 | Not Implemented |
CO0059 # 04 Y:1986 | 04 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $667 | $150 | Implemented |
CO0059 # 05 Y:1986 | 05 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $877 | $400 | Not Implemented |
CO0059 # 06 Y:1986 | 06 | 1986 | IMPROVE LUBRICATION PRACTICES | $621 | $0 | Not Implemented |
CO0059 # 07 Y:1986 | 07 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $314 | $50 | Implemented |
CO0059 # 08 Y:1986 | 08 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,338 | $160 | Implemented |
CO0059 # 09 Y:1986 | 09 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $770 | $1,380 | Not Implemented |
CO0059 # 10 Y:1986 | 10 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $5,248 | $55 | Implemented |
CO0059 # 11 Y:1986 | 11 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $740 | $655 | Implemented |
TN0254 # 01 Y:1985 | 01 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $3,422 | $1,042 | Implemented |