Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,938
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LT0041 # 03 Y:1985 | 03 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,008 | $450 | Implemented |
LT0041 # 04 Y:1985 | 04 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,080 | $264 | Implemented |
LT0041 # 06 Y:1985 | 06 | 1985 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $400 | $990 | Implemented |
LT0041 # 07 Y:1985 | 07 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,040 | $859 | Implemented |
LT0041 # 08 Y:1985 | 08 | 1985 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $650 | $42 | Implemented |
GT0271 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,850 | $830 | Implemented |
GT0271 # 02 Y:1985 | 02 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $27,600 | $35,000 | Implemented |
GT0271 # 03 Y:1985 | 03 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,149 | $2,978 | Implemented |
GT0271 # 04 Y:1985 | 04 | 1985 | IMPROVE LUBRICATION PRACTICES | $20,435 | $0 | Implemented |
GT0271 # 05 Y:1985 | 05 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,058 | $1,898 | Implemented |
GT0271 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $13,200 | $5,000 | Implemented |
MA0039 # 01 Y:1985 | 01 | 1985 | REPAIR OR REPLACE STEAM TRAPS | $10,926 | $455 | Implemented |
MA0039 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $2,276 | $703 | Implemented |
AT0015 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $236 | $272 | Implemented |
AT0015 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $132 | $180 | Implemented |
AT0015 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,213 | $2,322 | Implemented |
AT0015 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $738 | $922 | Implemented |
MA0032 # 06 Y:1985 | 06 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,902 | $2,400 | Implemented |
MA0032 # 07 Y:1985 | 07 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $485 | $120 | Implemented |
AT0011 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $514 | $691 | Implemented |
AT0011 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,520 | $0 | Implemented |
AT0011 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,390 | $24,300 | Implemented |
MA0034 # 01 Y:1985 | 01 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $944 | $325 | Implemented |
AT0012 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $396 | $300 | Implemented |
AT0012 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $6,139 | $275 | Implemented |