Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,239
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0582 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,310 | $9,200 | Not Implemented |
GT0582 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,210 | $7,600 | Implemented |
GT0582 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,000 | $36,900 | Implemented |
GT0582 # 04 Y:1996 | 04 | 1996 | USE SYNTHETIC LUBRICANT | $1,970 | $0 | Not Implemented |
GT0582 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,460 | $600 | Implemented |
GT0582 # 06 Y:1996 | 06 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $80,700 | $14,000 | Not Implemented |
GT0582 # 07 Y:1996 | 07 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $153,000 | $60,000 | Implemented |
GT0582 # 08 Y:1996 | 08 | 1996 | USE LESS WASTEFUL PACKAGING | $6,650 | $0 | Not Implemented |
AS0168 # 01 Y:1996 | 01 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $490 | $150 | Implemented |
AS0168 # 02 Y:1996 | 02 | 1996 | USE SYNTHETIC LUBRICANT | $468 | $124 | Implemented |
AS0168 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,596 | $0 | Implemented |
AS0168 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $306 | $300 | Not Implemented |
AS0168 # 05 Y:1996 | 05 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $38,756 | $1,750 | Implemented |
AS0168 # 06 Y:1996 | 06 | 1996 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $11,824 | $0 | Implemented |
AS0168 # 07 Y:1996 | 07 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,044 | $20,000 | Not Implemented |
AS0168 # 08 Y:1996 | 08 | 1996 | REDUCE HEAT GAIN BY WINDOW TINTING | $2,966 | $10,750 | Not Implemented |
AS0168 # 09 Y:1996 | 09 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,991 | $7,201 | Implemented |
AS0168 # 10 Y:1996 | 10 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $228 | $0 | Implemented |
AS0168 # 11 Y:1996 | 11 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,557 | $11,870 | Implemented |
AS0168 # 12 Y:1996 | 12 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,967 | $8,690 | Implemented |
AS0168 # 13 Y:1996 | 13 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,455 | $1,200 | Implemented |
OD0053 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,083 | $3,453 | Not Implemented |
OD0053 # 02 Y:1996 | 02 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,634 | $13,680 | Not Implemented |
OD0053 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,177 | $4,271 | Not Implemented |
OD0053 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,848 | $1,600 | Not Implemented |