Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

747

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0242 # 04 Y:2002 04 2002 INSULATE BARE EQUIPMENT $6,131 $10,062 Not Implemented
NC0242 # 05 Y:2002 05 2002 DEVELOP A REPAIR/REPLACE POLICY $547 $369 Implemented
NC0242 # 06 Y:2002 06 2002 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $2,368 $1,200 Implemented
NC0242 # 07 Y:2002 07 2002 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $5,981 $3,100 Implemented
NC0238 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN WATER LINES AND VALVES $1,890 $2,100 Implemented
NC0238 # 02 Y:2002 02 2002 REPAIR AND ELIMINATE STEAM LEAKS $3,389 $5,000 Implemented
NC0238 # 03 Y:2002 03 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,980 $26,000 Not Implemented
NC0238 # 04 Y:2002 04 2002 KEEP BOILER TUBES CLEAN $11,529 $50,000 Not Implemented
NC0238 # 05 Y:2002 05 2002 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $100,000 $35,000 Not Implemented
NC0238 # 06 Y:2002 06 2002 REPAIR OR REPLACE STEAM TRAPS $10,000 $9,340 Implemented
NC0238 # 07 Y:2002 07 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $1,112 $2,405 Implemented
NC0238 # 08 Y:2002 08 2002 INSULATE BARE EQUIPMENT $15,915 $5,922 Not Implemented
NC0238 # 09 Y:2002 09 2002 INSULATE BARE EQUIPMENT $14,570 $17,855 Not Implemented
NC0238 # 10 Y:2002 10 2002 INCREASE AMOUNT OF CONDENSATE RETURNED $4,818 $6,000 Implemented
NC0238 # 11 Y:2002 11 2002 DEVELOP A REPAIR/REPLACE POLICY $6,185 $17,736 Implemented
NC0238 # 12 Y:2002 12 2002 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $4,536 $1,500 Implemented
NC0238 # 13 Y:2002 13 2002 RECOVER WASTE HEAT FROM EQUIPMENT $93,319 $15,000 Implemented
NC0238 # 14 Y:2002 14 2002 UPGRADE OBSOLETE EQUIPMENT $3,325,357 $914,253 Not Implemented
NC0225 # 01 Y:2001 01 2001 DEVELOP A REPAIR/REPLACE POLICY $2,783 $1,895 Implemented
NC0225 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,625 $33,848 Implemented
NC0225 # 03 Y:2001 03 2001 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $27,745 $33,990 n/a
NC0225 # 04 Y:2001 04 2001 ELIMINATE COMBUSTIBLE GAS IN FLUE GAS $15,365 $5,000 Implemented
NC0225 # 05 Y:2001 05 2001 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $20,000 $40,000 n/a
NC0225 # 06 Y:2001 06 2001 KEEP BOILER TUBES CLEAN $3,649 $13,000 Implemented
NC0225 # 07 Y:2001 07 2001 REPAIR AND ELIMINATE STEAM LEAKS $8,655 $3,500 Implemented