Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,239

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0252 # 05 Y:1985 05 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,220 $4,800 Implemented
GT0252 # 06 Y:1985 06 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,490 $0 Implemented
GT0252 # 07 Y:1985 07 1985 RECOVER WASTE HEAT FROM EQUIPMENT $12,650 $10,000 Not Implemented
UD0159 # 01 Y:1985 01 1985 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $812 $0 Implemented
UD0159 # 02 Y:1985 02 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $219 $580 Implemented
UD0159 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,687 $218 Implemented
UD0159 # 04 Y:1985 04 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,961 $0 Implemented
UD0159 # 05 Y:1985 05 1985 RECOVER WASTE HEAT FROM EQUIPMENT $345 $920 Implemented
AT0006 # 01 Y:1985 01 1985 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,649 $4,661 Implemented
AT0006 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,976 $26,880 Implemented
AT0006 # 03 Y:1985 03 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $374 $9,984 Not Implemented
GT0250 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,550 $2,883 Implemented
GT0250 # 02 Y:1985 02 1985 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $979 $820 Implemented
GT0250 # 03 Y:1985 03 1985 REDUCE FLUID FLOW RATES $10,900 $25,000 Not Implemented
GT0250 # 04 Y:1985 04 1985 REPAIR AND ELIMINATE STEAM LEAKS $17,100 $800 Implemented
GT0250 # 05 Y:1985 05 1985 KEEP BOILER TUBES CLEAN $40,100 $50,000 Implemented
GT0250 # 06 Y:1985 06 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $99,000 $120,000 Not Implemented
GT0250 # 07 Y:1985 07 1985 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $191,000 $150,000 Not Implemented
GT0250 # 08 Y:1985 08 1985 INCREASE AMOUNT OF CONDENSATE RETURNED $156,100 $82,500 Not Implemented
GT0250 # 09 Y:1985 09 1985 MODIFY DYE BECK $146,000 $45,000 Implemented
GT0250 # 10 Y:1985 10 1985 CONTROL PRESSURE ON STEAMER OPERATIONS $102,000 $7,000 Implemented
AT0003 # 01 Y:1985 01 1985 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $189 $81 Implemented
AT0003 # 02 Y:1985 02 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $163 $0 Not Implemented
AT0003 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,417 $5,790 Not Implemented
TN0242 # 01 Y:1985 01 1985 REPAIR AND ELIMINATE STEAM LEAKS $5,384 $12 Implemented