Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,239

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0642 # 07 Y:1998 07 1998 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $35,596 $52,700 Not Implemented
GT0642 # 08 Y:1998 08 1998 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $14,022 $27,000 Not Implemented
GT0639 # 01 Y:1998 01 1998 COMBINE UTILITY METERS $10,670 $0 n/a
GT0639 # 02 Y:1998 02 1998 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,406 $5,000 n/a
GT0639 # 03 Y:1998 03 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,573 $0 n/a
GT0639 # 04 Y:1998 04 1998 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $200,000 $0 n/a
GT0639 # 05 Y:1998 05 1998 COVER OPEN TANKS $66,490 $87,860 n/a
GT0639 # 06 Y:1998 06 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,600 $10,500 n/a
GT0639 # 07 Y:1998 07 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,800 $1,000 n/a
GT0639 # 08 Y:1998 08 1998 METER WASTE WATER $1,180 $2,350 n/a
GT0639 # 09 Y:1998 09 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $13,480 $0 n/a
GT0626 # 01 Y:1997 01 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,741 $950 Implemented
GT0626 # 02 Y:1997 02 1997 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $21,185 $0 Implemented
GT0626 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,580 $11,230 Not Implemented
GT0626 # 04 Y:1997 04 1997 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $2,730 $1,420 Not Implemented
GT0626 # 05 Y:1997 05 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $400 $620 Implemented
GT0626 # 06 Y:1997 06 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,570 $7,580 Not Implemented
GT0626 # 07 Y:1997 07 1997 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $26,666 $4,200 Implemented
GT0626 # 08 Y:1997 08 1997 USE A DIFFERENT OR RECYCLED RAW MATERIAL $1,315 $438 Not Implemented
GT0622 # 01 Y:1997 01 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $980 $2,000 Implemented
GT0622 # 02 Y:1997 02 1997 REPAIR AND ELIMINATE STEAM LEAKS $3,470 $1,200 Implemented
GT0622 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $94 $240 Not Implemented
GT0622 # 04 Y:1997 04 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,626 $300 Implemented
GT0622 # 05 Y:1997 05 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,060 $632 Implemented
GT0622 # 06 Y:1997 06 1997 MINIMIZE WATER USAGE $533 $0 Not Implemented