Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,239
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0513 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $835 | $240 | Implemented |
NC0513 # 10 Y:2014 | 10 | 2014 | USE PHOTOCELL CONTROLS | $47 | $80 | Not Implemented |
NC0513 # 11 Y:2014 | 11 | 2014 | KEEP BOILER TUBES CLEAN | $48,265 | $15,000 | Implemented |
NC0513 # 12 Y:2014 | 12 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $40,007 | $6,200 | Implemented |
NC0513 # 13 Y:2014 | 13 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $20,840 | $20,000 | Implemented |
NC0513 # 14 Y:2014 | 14 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,159 | $5,600 | Not Implemented |
NC0513 # 15 Y:2014 | 15 | 2014 | KEEP BOILER TUBES CLEAN | $13,546 | $500 | Not Implemented |
NC0513 # 16 Y:2014 | 16 | 2014 | INSULATE FEEDWATER TANK | $438 | $257 | Implemented |
NC0513 # 17 Y:2014 | 17 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,435 | $19,607 | Not Implemented |
NC0513 # 18 Y:2014 | 18 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,375 | $37,264 | Not Implemented |
MA0729 # 01 Y:2014 | 01 | 2014 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $25,718 | $11,750 | Not Implemented |
MA0729 # 02 Y:2014 | 02 | 2014 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $14,490 | $500 | Implemented |
MA0729 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,956 | $3,300 | Implemented |
MA0729 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,114 | $9,050 | Not Implemented |
MA0729 # 05 Y:2014 | 05 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,622 | $2,690 | Not Implemented |
MA0729 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,173 | $200 | Implemented |
TT0127 # 01 Y:2014 | 01 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $34,016 | $68,097 | Not Implemented |
TT0127 # 02 Y:2014 | 02 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $73,188 | $228,000 | Not Implemented |
TT0127 # 03 Y:2014 | 03 | 2014 | INSTALL COMMON HEADER ON COMPRESSORS | $5,171 | $25 | Not Implemented |
TT0127 # 04 Y:2014 | 04 | 2014 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $600 | $25 | Implemented |
TT0127 # 05 Y:2014 | 05 | 2014 | DISCONNECT BALLASTS | $390 | $130 | Implemented |
NC0510 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $55,430 | $1,200 | Implemented |
NC0510 # 02 Y:2014 | 02 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,472 | $4,800 | Not Implemented |
NC0510 # 03 Y:2014 | 03 | 2014 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $1,500 | $1,000 | Implemented |
NC0510 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $39,042 | $3,000 | Not Implemented |