Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,239
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0313 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,365 | $25,000 | Implemented |
LE0313 # 02 Y:2011 | 02 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,529 | $16,000 | Not Implemented |
LE0313 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,031 | $960 | Implemented |
LE0313 # 04 Y:2011 | 04 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $7,324 | $20,000 | Not Implemented |
LE0313 # 05 Y:2011 | 05 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $5,313 | $960 | Implemented |
LE0313 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,587 | $105,000 | Implemented |
LE0313 # 07 Y:2011 | 07 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,422 | $200 | Not Implemented |
LE0313 # 08 Y:2011 | 08 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,655 | $0 | Not Implemented |
LE0313 # 09 Y:2011 | 09 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $559 | $315 | Implemented |
LE0313 # 10 Y:2011 | 10 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,746 | $16,016 | Not Implemented |
LE0313 # 11 Y:2011 | 11 | 2011 | INSTALL OCCUPANCY SENSORS | $1,827 | $2,302 | Not Implemented |
LE0313 # 12 Y:2011 | 12 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,016 | $1,814 | Not Implemented |
MI0202 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $24,647 | $9,000 | Implemented |
MI0202 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,531 | $62,700 | Implemented |
MI0202 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,679 | $1,320 | Implemented |
MI0202 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $2,481 | $6,700 | Not Implemented |
MI0202 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,001 | $1,980 | Not Implemented |
MI0202 # 06 Y:2011 | 06 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,267 | $50 | Implemented |
SD0504 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,200 | $12,725 | Not Implemented |
SD0504 # 02 Y:2010 | 02 | 2010 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $188,550 | $211,240 | Not Implemented |
SD0504 # 03 Y:2010 | 03 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $14,846 | $20,000 | Not Implemented |
SD0504 # 04 Y:2010 | 04 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,360 | $7,010 | Not Implemented |
SD0504 # 05 Y:2010 | 05 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,983 | $11,585 | Not Implemented |
GT0876 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,786 | $1,500 | Implemented |
GT0876 # 02 Y:2010 | 02 | 2010 | INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE | $307 | $50 | Not Implemented |