Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,239

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0155 # 03 Y:1998 03 1998 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $441 $50 Not Implemented
NC0155 # 04 Y:1998 04 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $386 $0 Not Implemented
NC0155 # 05 Y:1998 05 1998 AIR CONDITION ONLY SPACE NECESSARY $3,045 $5,426 Not Implemented
NC0155 # 06 Y:1998 06 1998 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $15,130 $9,000 Not Implemented
NC0155 # 07 Y:1998 07 1998 CLEAR AND RENT EXISTING SPACE $50,000 $150,000 Not Implemented
HO0171 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,328 $30,330 Not Implemented
HO0171 # 02 Y:1998 02 1998 INSTALL OCCUPANCY SENSORS $5,886 $2,000 Not Implemented
HO0171 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,021 $5,131 Implemented
HO0171 # 04 Y:1998 04 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,188 $50 Implemented
HO0171 # 05 Y:1998 05 1998 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,531 $3,500 Not Implemented
HO0171 # 06 Y:1998 06 1998 INSULATE BARE EQUIPMENT $383 $190 Not Implemented
HO0171 # 07 Y:1998 07 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $54,070 $24,050 Not Implemented
HO0171 # 08 Y:1998 08 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $64,007 $2,200 Implemented
HO0171 # 09 Y:1998 09 1998 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $10,116 $1,000 Implemented
MS0102 # 01 Y:1998 01 1998 OPTIMIZE PLANT POWER FACTOR $22,934 $8,025 Not Implemented
MS0102 # 02 Y:1998 02 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $16,041 $0 Implemented
MS0102 # 03 Y:1998 03 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,038 $1,930 Implemented
MS0102 # 04 Y:1998 04 1998 USE OPTIMUM TEMPERATURE $17,981 $0 Implemented
MS0102 # 05 Y:1998 05 1998 TURN OFF STEAM TRACING DURING MILD WEATHER $5,726 $0 Implemented
MS0102 # 06 Y:1998 06 1998 INSTALL TIMERS AND/OR THERMOSTATS $7,306 $47 Implemented
MS0102 # 07 Y:1998 07 1998 RECOVER WASTE HEAT FROM EQUIPMENT $4,227 $8,447 Not Implemented
MS0102 # 08 Y:1998 08 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $14,767 $22,372 Not Implemented
MS0102 # 09 Y:1998 09 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $7,369 $0 Implemented
MS0102 # 10 Y:1998 10 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $7,480 $6,500 Implemented
MS0102 # 11 Y:1998 11 1998 ELIMINATE SHIFT $489,216 $0 Implemented